Error description
Traceback information in a CEEDUMP may provide an incorrect statement number in reference to a COBOL program.
Local fix
Compile with OPT(0)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling * * programs at OPT(1|2) and containing at * * least two MOVE statements where the senders * * are smaller than the receivers, the first * * MOVE is either not a reference modification * * or is a reference modification where the * * start and length are literals, and at least * * one of the start and length in the second * * MOVE are data items. * **************************************************************** * PROBLEM DESCRIPTION: An LHI instruction generated for the * * second MOVE has the line number of the * * first MOVE statement. * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** Generation of the LHI Instruction in the first MOVE statement is postponed to the second MOVE statement, leading to a different line number assigned to the instruction.
Problem conclusion
The compiler was fixed to update the line number in above case.
Temporary fix
Comments
APAR Information
APAR number
PH57688
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-10-20
Closed date
2023-10-23
Last modified date
2023-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UI94116
UP23/11/01 P F310
R641 PSY UI94117
UP23/11/01 P F310
R642 PSY UI94118
UP23/11/01 P F310
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 November 2023