Error description
In Chart of Accounts the Deactivate GL Validations? box is checked (client is not using GL Accounts) and the task is made required in Quick Reporting. Then click the Start Timer, the Labor is auto populated, enter the required task 10 to the labor, when the timer is stopped error 'BMXAA2554E - Timer not started.' is displayed. STEPS TO REPRODUCE: 1. Go to Quick Reporting application and open any WO or Create new wo Created WO: 1381DF Location: BR240 2. Next, create a new task and change status to INPRG In the Task section Click New Row Task: 10 Summary: testing the timer error on end time Reference WO: T1290 Location: BR240 Asset: 11240 Estimated Duration: 0:05 Status: INPRG Save 3. Next click on More actions and select Start timer Common Actions > Start Timer Click the Start Timer 4. This will create a Labor record and then assign the task we created Labor sub tab Created Labor: WILSON Task: 10 - entered the task number from above Start Date: 9/14/23 Start Time: 6:28 PM Regular Hours: 0:05 5. Click on Stop Timer and we get the error. Common Actions > Stop Timer Results: Once you click the Stop Time you receive the System Message: BMXAA2554E - Timer not started. Expected Results: Not to receive the message and able to stop the timer. ***Note: If the Task is not used, the stop timer works correctly REPORTED IN VERSION: 7.6.1.3-IFIX20230727-1457 (IF010)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * _MAXIMO_ * **************************************************************** * PROBLEM DESCRIPTION: * * TIMER NOT STARTED WHEN USING TIMER IN QUICK REPORTING WHEN * * TRYING TO STOP TIMER * **************************************************************** The timer not started error appeared while trying to stop the timer in the quick reporting application. The problem happened due to incorrect or missed checking of wonum when any task is applied after starting the timer, due to which there was no timer record found with status active and it displayed the error - timer not started.
Problem conclusion
The fix for this APAR will be contained in a future release.
Temporary fix
Comments
APAR Information
APAR number
IJ48909
Reported component name
MAXIMO ASST MGM
Reported component ID
5724R46AM
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-10-16
Closed date
2023-10-20
Last modified date
2023-10-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO ASST MGM
Fixed component ID
5724R46AM
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
20 October 2023