IBM Support

IJ48890: CHANGING THE DATA TYPE FROM AN ATTRIBUTE IN CLASSIFICATION APPLICATION IS NOT REFLECTING THE CHANGE WHILE USER USES THE CLASSIFI

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Problem Description
    User is changing a data type from NUMERIC to ALN from an
    attribute in classification application but it's not reflecting
    while user use it in Asset application. Every time user
    classifies an asset record with the classification, it is
    showing the specification with Alphanumeric read only and
    Numeric value field open to user enter a value.
    
    STEPS TO REPRODUCE:   clear recreate steps that make sense to
    someone not involved in PMR/Case.
    .GO TO >> ADMINISTRATION >> CLASSIFICATION
    .Create a new classification
    .Classification: TEST001
    .Click YES in the system message
    .Organization: EAGLENA
    .Site: BEDFORD
    .Save
    .In Use With section, add a new row
    .Use With Object: ASSET
    .In Attributes section, add a new row
    .Attribute: NUM_ORIG
    .tab out
    .In the question mark, click YES to add it
    .Data Type: NUMERIC
    .Add second new row
    .Attribute: ALN_ORIG
    .tab out
    .In the question mark, click YES to add it
    .Data Type: ALN
    .Save
    
    .GO TO >> ASSETS >> ASSETS
    .Brig up any existing asset and open it (IE 13180)
    .Click in Specifications tab
    .In classification field, classify with the classification we
    created in the second step
    .Enter the following informtion
    NUM_ORIG - Numeric Value: 2.0
    ALN_ORIG - Alphaumeric Value: ABC1000
    .Save
    
    .GO TO >> ADMINISTRATION >> CLASSIFICATION
    .In Attributes section, delete line for NUM_ORIG attribute.
    .Click YES
    .Save
    .SELECT ACTIONS >> ADD/Modify Properties >> Attributes
    .Delete NUM_ORIG attribute as well
    .Click OK
    .Add a new row in Attribute section
    .Attribute: NUM_ORIG
    .tab out
    .In the question mark, click YES to add it
    .Data Type: ALN
    .Save
    
    .GO TO >> ASSETS >> ASSETS
    .Bring the same asset again (ie 13180)
    .Click in Specification tab
    . Reclassify the asset with same classification
    
    RESULTS: Alphanumeric field is read only and user can't enter
    any value for an specification with type ALN. Specifications
    remains as numeric type.
    
    EXPECTED RESULTS:   User expects to be able to enter a value in
    Alphanumeric field in Asset application after change the data
    type for an attribute in classification.
    
    REPORTED IN VERSION:
    
    Tivoli's process automation engine 7.6.1.2
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * MAXIMO                                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Changing the data type from an attribute in classification   *
    * application is not reflecting the change while user uses the *
    * classification to classify an asset.                         *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR will be contained in a future release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ48890

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-10-13

  • Closed date

    2023-10-31

  • Last modified date

    2023-10-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
31 October 2023