APAR status
Closed as program error.
Error description
Problem Description User is changing a data type from NUMERIC to ALN from an attribute in classification application but it's not reflecting while user use it in Asset application. Every time user classifies an asset record with the classification, it is showing the specification with Alphanumeric read only and Numeric value field open to user enter a value. STEPS TO REPRODUCE: clear recreate steps that make sense to someone not involved in PMR/Case. .GO TO >> ADMINISTRATION >> CLASSIFICATION .Create a new classification .Classification: TEST001 .Click YES in the system message .Organization: EAGLENA .Site: BEDFORD .Save .In Use With section, add a new row .Use With Object: ASSET .In Attributes section, add a new row .Attribute: NUM_ORIG .tab out .In the question mark, click YES to add it .Data Type: NUMERIC .Add second new row .Attribute: ALN_ORIG .tab out .In the question mark, click YES to add it .Data Type: ALN .Save .GO TO >> ASSETS >> ASSETS .Brig up any existing asset and open it (IE 13180) .Click in Specifications tab .In classification field, classify with the classification we created in the second step .Enter the following informtion NUM_ORIG - Numeric Value: 2.0 ALN_ORIG - Alphaumeric Value: ABC1000 .Save .GO TO >> ADMINISTRATION >> CLASSIFICATION .In Attributes section, delete line for NUM_ORIG attribute. .Click YES .Save .SELECT ACTIONS >> ADD/Modify Properties >> Attributes .Delete NUM_ORIG attribute as well .Click OK .Add a new row in Attribute section .Attribute: NUM_ORIG .tab out .In the question mark, click YES to add it .Data Type: ALN .Save .GO TO >> ASSETS >> ASSETS .Bring the same asset again (ie 13180) .Click in Specification tab . Reclassify the asset with same classification RESULTS: Alphanumeric field is read only and user can't enter any value for an specification with type ALN. Specifications remains as numeric type. EXPECTED RESULTS: User expects to be able to enter a value in Alphanumeric field in Asset application after change the data type for an attribute in classification. REPORTED IN VERSION: Tivoli's process automation engine 7.6.1.2
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * MAXIMO * **************************************************************** * PROBLEM DESCRIPTION: * * Changing the data type from an attribute in classification * * application is not reflecting the change while user uses the * * classification to classify an asset. * ****************************************************************
Problem conclusion
The fix for this APAR will be contained in a future release.
Temporary fix
Comments
APAR Information
APAR number
IJ48890
Reported component name
MAXIMO ASST MGM
Reported component ID
5724R46AM
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-10-13
Closed date
2023-10-31
Last modified date
2023-10-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO ASST MGM
Fixed component ID
5724R46AM
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
31 October 2023