A fix is available
APAR status
Closed as program error.
Error description
Collection of fixes
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM z/OS Change Tracker. * **************************************************************** * PROBLEM DESCRIPTION: 1. Restore of member in z/OS Change * * Tracker fails with 0C1. * * 2. Loop when tokenizing a PDSE. * * 3. IEBCOPY from a locked data set * * fails. * * 4. SHOW=UNIVERSE mis-reports checked * * out members of uncataloged data * * sets. * * 5. Unable to check out a member from an * * uncataloged data set. * * 6. Erroneous CYG249W message when * * unprotecting an uncataloged data * * set. * * 7. SHOW=ACTIONS output from ISPF * * foreground invocation is missing * * headings. * * 8. Abend 0C7 in CYGSYSIO. * * 9. Error in CYGK3CRE sample job. * * 10. UNPROTECT returns RC=0 when it * * fails. * * 11. REN and UPD options swapped on * * Audit panel CYGGSTC. * * 12. Invalid CYG227E message from the * * CYGUREC5 panel (Backup Versions of * * Member). * * 13. Validation of the Token file field * * on the CYGODIR0 Tokenize a z/OS * * Unix Directory panel is incorrect. * * 14. Recovery of different versions of a * * backed-up member fails. * * 15. ISPF delete backup generates JCL * * with ARCHIVEBACKUP instead of * * DELETEBACKUP. * * 16. Started task refresh delay is * * unnecessarily long. * * 17. Uncontrolled shutdown after started * * task abend. * * 18. Unnecessary processing of data sets * * opened for input only. * * 19. Prevent REPROTECT LOCK=N when data * * set has checked-out members. * * 20. INITIAL=NEVER data sets erroneously * * displayed on the ISPF Recover panel * * list. * * 21. Inconsistent layout and minor * * errors on both English and Japanese * * ISPF panels. * **************************************************************** * RECOMMENDATION: Apply the provided PTF(s). * **************************************************************** 1. Abend 0C1 when attempting to recover a member to a PDSE. 2. Tokenization of a PDSE member loops when error encountered. 3. Change Tracker prevents IEBCOPY from a locked data set. 4. SHOW=UNIVERSE mis-reports checked out members of uncataloged data sets. 5. Error when attempting to check out a member from an uncataloged data set. 6. Erroneous CYG249W message when unprotecting an uncataloged data set. 7. The ISPF SHOW=ACTIONS report from ISPF foreground invocation is missing headings. 8. An abend 0C7 occurs when tokenizing a PDSE member. 9. A JCL error occurs when attempting to run the CYGK3CRE sample job. 10. The UNPROTECT command returns RC=0 when it fails. 11. The REN and UPD options are incorrectly labeled on the CYGGSTC Audit panel. 12. Cannot select different members on the ISPF recovery panel. 13. Incorrect validation of the token file field on the CYGODIR0 Tokenize a z/OS Unix Directory panel. 14. The ISPF Recover panel allows different versions of a backed up member to be selected. 15. ISPF delete backup generates JCL with the ARCHIVEBACKUP command instead of the DELETEBACKUP command. 16. The started task refresh delay time needs to be reduced. 17. Add an ESTAE exit to ensure a controlled shutdown if the started task abends. 18. Modify the CLOSE SVC exit to ignore data sets opened for input only. 19. Prevent a locked data set from being unlocked when it has checked out members. 20. Remove INITIAL=NEVER data sets from the ISPF Recover panel list. 21. Tidy up of English and Japanese ISPF panels.
Problem conclusion
1. An error message is now issued if the specified recovery data set is a PDSE. 2. Error message CYG641W is now issued when a tokenization error occurs. 3. Data sets opened for input only are now ignored. 4. SHOW=UNIVERSE correctly reports uncataloged data sets. 5. Members of uncataloged data sets can now be checked-out. 6. UNPROTECT of uncataloged data sets now runs successfully. 7. The ISPF SHOW=ACTIONS foreground report now displays headings. 8. The handling of date errors in PDSE members is improved to avoid abends. 9. The CYGK3CRE sample job is corrected. 10. An warning message is now issued if the UNPROTECT command fails. 11. The REN and UPD lebels on the CYGGSTC Audit panel have been corrected. 12. The ISPF recovery panel is changed to allow selection of multiple different members. 13. The ISPF Tokenize a z/OS Unix Directory panel token file field validation is corrected. 14. The ISPF Recover panel is changed to allow selection of only one version of any member. 15. The ISPF Delete Backup panel now generates the DELETEBACKUP command instead of the ARCHIVEBACKUP command. 16. The started task refresh interval is reduced from 1 minute to 5 seconds. 17. An ESTAE exit has been added to ensure a controlled shutdown if the started task abends. 18. The CLOSE SVC exit has been modified to ignore data sets opened for input only. 19. The REPROTECT command with LOCK=NO now cannot be executed for a data set with checked-out members. 20. Data sets protected with INITIAL=NEVER no longer appear on the ISPF recovery panel. 21. Minor corrections and updates have been made to both English and Japanese ISPF panels.
Temporary fix
Comments
APAR Information
APAR number
PH57444
Reported component name
Z/OS CHANGE TRA
Reported component ID
5752SCCYG
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-10-11
Closed date
2024-01-03
Last modified date
2024-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI95105 UI95106
Modules/Macros
CYG22 CYG94 CYGCBKP CYGCBKPL CYGCBKPS CYGCOMM CYGERROR CYGEXIT CYGGARC1 CYGGARC2 CYGGARC3 CYGGARC4 CYGGARCA CYGGARCB CYGGCKO1 CYGGCKO2 CYGGCKO3 CYGGCKOL CYGGEMPT CYGGLOG1 CYGGMOD CYGGREC1 CYGGREC2 CYGGREC3 CYGGREC4 CYGGREM CYGGRESD CYGGSHO1 CYGGSHO2 CYGGSHOW CYGGSTC CYGGUNC0 CYGGUNC1 CYGHACTN CYGHADF2 CYGHADF3 CYGHADF4 CYGHADF5 CYGHADF6 CYGHADF7 CYGHADF8 CYGHADF9 CYGHADFA CYGHADFC CYGHADFR CYGHADFS CYGHADMN CYGHALRT CYGHARC2 CYGHARC3 CYGHARCA CYGHARCB CYGHBKF1 CYGHBKP1 CYGHCATL CYGHCBKP CYGHCKCM CYGHCKER CYGHCKI1 CYGHCKI2 CYGHCKIC CYGHCKO1 CYGHCKO2 CYGHCMF1 CYGHCMF3 CYGHCMF4 CYGHCMF5 CYGHCMF6 CYGHCMF7 CYGHCMH1 CYGHCMH2 CYGHCMT CYGHCOMD CYGHCOP1 CYGHCOP2 CYGHDEL1 CYGHDIRL CYGHDRDR CYGHDRF1 CYGHDRF2 CYGHDRF3 CYGHDRF4 CYGHDRF5 CYGHDRF6 CYGHDRFD CYGHDRFF CYGHDRFI CYGHDRFP CYGHDRPS CYGHDRRP CYGHDRSY CYGHDRTC CYGHDRTK CYGHEXPL CYGHFRVL CYGHGCPY CYGHGDAY CYGHGLOB CYGHGPF2 CYGHGPF3 CYGHGPF4 CYGHGRC1 CYGHGRC2 CYGHGRC3 CYGHGRC4 CYGHGREM CYGHGRP1 CYGHGRP2 CYGHGRP3 CYGHGRP4 CYGHGRPT CYGHGRV1 CYGHGRV3 CYGHIDEN CYGHIEB CYGHJOBN CYGHLCMD CYGHLOG1 CYGHMACC CYGHMAIN CYGHMBAK CYGHMCF1 CYGHMCF2 CYGHMCF3 CYGHMCF4 CYGHMCF5 CYGHMCKI CYGHMDR CYGHMGLO CYGHMGMT CYGHMOD CYGHMOD1 CYGHMOD2 CYGHMODU CYGHMOPT CYGHMREC CYGHMUTL CYGHOCF1 CYGHOCF2 CYGHOCF3 CYGHOCHG CYGHOCMP CYGHODIR CYGHOLF1 CYGHOLIS CYGHOMF0 CYGHOMF1 CYGHOMF2 CYGHOMF3 CYGHOMF4 CYGHOMF5 CYGHOMF6 CYGHOMF7 CYGHOMF8 CYGHOMF9 CYGHOMOD CYGHOMPT CYGHOMVS CYGHOPER CYGHOPTN CYGHPAF5 CYGHPAF6 CYGHPAF7 CYGHPAF8 CYGHPAR2 CYGHPARM CYGHRCOV CYGHREC1 CYGHREC2 CYGHREC3 CYGHREF1 CYGHREFL CYGHREPO CYGHREQD CYGHRESD CYGHRLF2 CYGHRLF3 CYGHRLF4 CYGHRMO1 CYGHRMO2 CYGHRMOD CYGHRSF0 CYGHRSF1 CYGHRSF2 CYGHSECA CYGHSHO1 CYGHSHO2 CYGHSHOW CYGHSTC CYGHTOK CYGHTOK1 CYGHTOK2 CYGHTOVL CYGHUNC0 CYGHUNC1 CYGHUREP CYGHUSP1 CYGHUSP2 CYGHUSU0 CYGHUSU1 CYGHUSU2 CYGHUTIL CYGHVOLM CYGHVOLO CYGK3CRE CYGLOCK1 CYGLOCK2 CYGMAIN CYGMGLOB CYGMLPCL CYGMLPOP CYGMLPST CYGMMAIN CYGMOD CYGMOMVS CYGMSGS CYGOCHG CYGOCMP CYGODIR CYGODIR0 CYGOLIST CYGPODR CYGPX001 CYGQAUDT CYGQGLOB CYGQRCOV CYGQSUPC CYGRMENU CYGRREP CYGRTOK1 CYGRTOK2 CYGRTOKA CYGRTOKB CYGRTOKD CYGRVTOC CYGSTC CYGSYSIO CYGTKEXT CYGTKREF CYGTOKEN CYGUCKI1 CYGUCKI2 CYGUCMP1 CYGUCMP2 CYGUCMP3
Fix information
Fixed component name
Z/OS CHANGE TRA
Fixed component ID
5752SCCYG
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"100"}]
Document Information
Modified date:
01 February 2024