A fix is available
APAR status
Closed as program error.
Error description
OMPE V550 NOVEMBER 2023 MAINTENANCE UPDATES
Local fix
na
Problem summary
**************************************************************** * USERS AFFECTED: Classic Interface users * * Batch RECTRACE users * * Batch STATISTICS users * * Batch ACCOUNTING users * * Enhanced 3270 UI users * * Near Term History Users * **************************************************************** * PROBLEM DESCRIPTION: 1. ATF zoom incorrect behaviors. * * 2. KDPSSQLS: invalid value for * * 'Expansion reason' column * * 3. Thread History "Thread indicator" * * help outdated * * 4. KDPEDMN Interval in seconds should * * be moved to separate sub-panel * * 5. INCORROUT for RECTRACE QW0006PG * * 6. QISTINPR/QISTINPE (IAG2) INCORROUT * * in Batch STATISTICS report * * 7. INCORROUT in E3270UI KDPLOGSB "Log * * Manager Statistics" for Delta and * * Rate values * * 8. No data collected from Near Term * * History. * * 9. IFCID 350 trace not started when * * DYNAMICSQL(FULL) option selected in * * Near Term History collector. * * 10. INCORROUT in Classic screen ZUTIA * * displaying utility phase * * 11. KDPBPD54 duplicate columns in table * * and column name for QBSTWKPD * * truncated. * * 12. Situation data request for E3270 * * Thread History tables is causing * * KO2D0013E error in log. * * 13. Data set extent event information * * INCORROUT after collector restart. * * 14. No daybreak information printed * * in E3270 Thread History panels. * * 15. INCORROUT in Classic ZDFST screen. * * 16. Message KO2D0009E displayed in log. * * 17. ROLLUP_THREADS column is 0 for * * non-rollup threads in Accounting * * PDB. * **************************************************************** * RECOMMENDATION: Apply the recommended PTF. * **************************************************************** 1. Data from previous zoom is displayed on various ATF panels. 2. KDPSSQLS: invalid value for 'Expansion reason' column 3. Thread History "Thread indicator" help outdated 4. KDPEDMN Interval in seconds should be moved to separate sub-panel 5. INCORROUT for RECTRACE field QW0006PG 6. QISTINPR/QISTINPE (IAG2) INCORROUT in Batch STATISTICS 7. INCORROUT in E3270UI panel KDPLOGSB "Log Manager Statistics" for Delta and Rate values 8. Missing performance trace from NTH start causing no data displayed from ZH2RC 9. IFCID 350 trace not started when DYNAMICSQL(FULL) option is selected in Near Term History collector. 10. INCORROUT in Classic screen ZUTIA displaying utility phase 11. E3270 panel KDPBPD54 has duplicate columns in table and column name for QBSTWKPD is truncated. 12. A situation defined on any E3270 Thread History table is causing a KO2D0013E error in log. 13. Data set extent event information INCORROUT after collector restart. 14. No daybreak information printed in E3270 Thread History panels. 15. INCORROUT in Classic ZDFST screen "HWM Inactive DBATs". 16. Messages like "KO2D0009E QBF4 FR_addCriteria NTHPLAN - Return Code:00000004 - Reason Code:00605403 (KO2AHLR)" are displayed in log due to missing input validation. 17. ROLLUP_THREADS column is 0 for non-rollup threads in Batch Accounting PDB table DB2PMFACCT_PROGRAM.
Problem conclusion
1. Corrected ATF zoom bahavior on ATVC, ATVW, ATVD and ATVS. 2. Corrected value for 'Expansion reason' column. 3. Corrected "Thread Indicator" help on Thread History summaries 4. KDPEDMN Interval in seconds moved to separate sub-panel. 5. Corrected RECTRACE field QW0006PG formatting. 6. Corrected QISTINPR/QISTINPE (IAG2) Batch STATISTICS report. 7. Corrected logic to calculate Delta and Rate values properly in panel KDPLOGSB "Log Manager Statistics". 8. Corrected logic to start performance trace at NTH start time. 9. Logic was corrected to start IFCID 350 properly when option DYNAMICSQL(FULL) is selected in NTH. 10. Corrected Classic screen ZUTIA display logic for utility phase to remove extra character. 11. E3270 panel KDPBPD54 definition has been corrected to not show a duplicate column name and not truncate column QBSTWKPD. 12. Code logic has been corrected to prevent the display of error message KO2D0013E in the log. 13. Code logic to read data set extent event information from the event data set has been corrected. 14. E3270 Thread History workspace definitions have been adjusted to display daybreak. 15. Classic ZDFST screen "HWM Inactive DBATs" counter refactored in "HWM Inactive Type 1 DBAT" + "HWM Type 2 Inactive Conn". Also added "Current Type 2 Inact Conn" counter. 16. Thread History filter screens have been enhanced for better input value validation to avoid message KO2D0009E. 17. Set ROLLUP_THREADS value to 1 for non-rollup threads in Batch Accounting PDB table. Keywords ATF ZOOM KDPSSQLS KDPEDMN QW0006PG QISTINPR QISTINPE IAG2 KDPLOGSB ZH2RC IFCID350 ZUTIA KDPBPD54 QBSTWKPD KO2D0013E ZDFST
Temporary fix
Comments
APAR Information
APAR number
PH57436
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
550
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-10-10
Closed date
2023-11-16
Last modified date
2024-03-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI94506
Modules/Macros
DGOAACUM DGOABORD DGOABORE DGOACALC DGOACMER DGOACOMP DGOACREC DGOADNOR DGOAEX20 DGOAEXIT DGOAFGEN DGOAFILE DGOAFLAT DGOAFORM DGOAFPCK DGOAIREC DGOAIREP DGOALUMP DGOAMTRC DGOAQKEY DGOARCAL DGOAREDB DGOAREDC DGOAREDD DGOAREDG DGOAREDI DGOAREDM DGOAREDP DGOAREDR DGOAREDX DGOASAVE DGOATOPR DGOATPRC DGOATRAC DGOATREC DGOAZMER DGOAZREC DGOBARAL DGOBARDD DGOBARLK DGOBARLO DGOBARPK DGOBARPO DGOBARPT DGOBARRI DGOBARRL DGOBARSH DGOBARSP DGOBARSQ DGOBARTE DGOBARTM DGOBATAL DGOBATDD DGOBATLK DGOBATLO DGOBATPK DGOBATPO DGOBATPT DGOBATRI DGOBATRL DGOBATSH DGOBATSP DGOBATSQ DGOBATTM DGOBGENL DGOBSRAL DGOBSRBN DGOBSRCM DGOBSRDD DGOBSRLG DGOBSRLK DGOBSRLO DGOBSROC DGOBSRPO DGOBSRQP DGOBSRRI DGOBSRSH DGOBSRSP DGOBSRSQ DGOBSRSS DGOBSRTM DGOBSTAL DGOBSTBN DGOBSTCM DGOBSTDD DGOBSTLG DGOBSTLK DGOBSTLO DGOBSTOC DGOBSTPO DGOBSTQP DGOBSTRI DGOBSTSH DGOBSTSP DGOBSTSQ DGOBSTSS DGOBSTTM DGOER000 DGOFECAL DGOFEDAT DGOFEPKG DGOFPDAT DGOFPRIC DGOMEGST DGONF012 DGONFLST DGONSLCK DGOPAB10 DGOPAC10 DGOPAC20 DGOPACNV DGOPMICO DGORAEXT DGORIREP DGORPACC DGORUACC DGORZREP DGOSACUM DGOSBLKX DGOSBORD DGOSBORE DGOSCREC DGOSREPM DGOSSAVE DGOVEE00 DGOVEE01 DGOVEEDI DGOVEEDR DGOVEEDS DGOVEEDT DGOVPMOV DGOVUAS0 DGOVUELD DGOVUM00 DGOVUSS0 FPECMDAT FPEUCBPR KD5AGENT KDPBP54 KDPEDMN KDPHHTHD KDPHISLA KDPHISLB KDPHISLD KDPHISLS KDPHISTL KDPHNREX KDPHSSQL KDPLOGSB KDPSTRTH KO2ACA02 KO2ACA0A KO2ACA0S KO2ACA32 KO2ACA3A KO2ACA3S KO2ACAF2 KO2ACAFA KO2ACAFS KO2ACAP2 KO2ACAPA KO2ACAPS KO2AHLR KO2APC12 KO2APC1A KO2APC1S KO2APC22 KO2APC2A KO2APC2S KO2APCN2 KO2APCNA KO2APCNS KO2ASU02 KO2ASU0A KO2ASU0S KO2ASU12 KO2ASU1A KO2ASU1S KO2ASU22 KO2ASU2A KO2ASU2S KO2ASU32 KO2ASU3A KO2ASU3S KO2ASU42 KO2ASU4A KO2ASU4S KO2ASU52 KO2ASU5A KO2ASU5S KO2ASU62 KO2ASU6A KO2ASU6S KO2ASU72 KO2ASU7A KO2ASU7S KO2ASU82 KO2ASU8A KO2ASU8S KO2ASU92 KO2ASU9A KO2ASU9S KO2ASUA2 KO2ASUAA KO2ASUAS KO2ASUB2 KO2ASUBA KO2ASUBS KO2ASUD2 KO2ASUDA KO2ASUDS KO2ATBMB KO2ATQXB KO2ATRCB KO2ATRPB KO2ATVCB KO2ATVDB KO2ATVSB KO2ATVWB KO2CDFC2 KO2CDFCA KO2CDFCS KO2CIFDB KO2CSTSB KO2CSY12 KO2CSY1A KO2CSY1S KO2CSYS2 KO2CSYSA KO2CSYSS KO2DFSTH KO2HHRCB KO2HPR2B KO2HPRCB KO2HWLMB KO2ICOL2 KO2ICOLA KO2ICOLS KO2IINTB KO2NCS6B KO2ODBGB KO2ODCNB KO2ODSTB KO2OH2IB KO2OINTB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R550 PSY UI94506
UP23/11/18 P F311
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"550","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: