IBM Support

PH57196: ABO ASSERTION FAILED AT ./BINDER.CPP:3662: ISCODECLASS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABO Assertion failed at ./Binder.cpp:3662: isCodeClass
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Automatic Binary Optimizer      *
    *                 (ABO) for z/OS, 2.2 and ABO for z/OS 2.2     *
    *                 Trial                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: In rare cases, COBOL programs may       *
    *                      result in a "Assertion failed at        *
    *                      ./Binder.cpp:3662: isCodeClass" failure *
    *                      when optimized by ABO. This happens due *
    *                      to ABO incorrectly processing text data *
    *                      found in some COBOL programs.           *
    ****************************************************************
    * RECOMMENDATION: Apply provided service                       *
    ****************************************************************
    ABO was modified to correctly optimize programs containing the
    affected type of text data.
    

Problem conclusion

  • ABO was modified to correctly optimize these types of input
    modules.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH57196

  • Reported component name

    AUTO BINARY OPT

  • Reported component ID

    5697AB200

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-09-27

  • Closed date

    2023-10-06

  • Last modified date

    2023-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI93913 UI93914

Modules/Macros

  • BOZAUPLE BOZBXITA BOZCIAPJ BOZCICPJ BOZCICPR BOZCICSJ BOZCICSR
    BOZEXE1  BOZGLUE  BOZJCLE  BOZJIVP  BOZMCTPA BOZMSGE  BOZMSGK
    BOZMSGT  BOZOBJ1  BOZOBJ2  BOZOPT   BOZPA    BOZPAJ   BOZRIDT
    BOZSETRT BOZSMF   BOZSMFJ  BOZSMFR  BOZSRC1  BOZSRC2  BOZTRUE
    

Fix information

  • Fixed component name

    AUTO BINARY OPT

  • Fixed component ID

    5697AB200

Applicable component levels

  • R220 PSY UI93913

       UP23/10/11 P F310

  • R22J PSY UI93914

       UP23/10/11 P F310

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"220"}]

Document Information

Modified date:
02 November 2023