A fix is available
APAR status
Closed as program error.
Error description
Compiler abends with message Assertion failed at ./CodeGenRA.cpp:120: !regsAreLive
Local fix
Compile with OPT(0) or ARCH(12) and below.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling * * programs at OPT(1|2) and ARCH(13) that * * contain an INSPECT TALLYING statement where * * the inspected item is alphanumeric and has * * length greater than one and where the * * inspected item is reference-modified, with * * the length unspecified. The inspected item * * must then be used as a sender in a MOVE * * statement, where it is also * * reference-modified, this time with both the * * start position and length specified. * **************************************************************** * PROBLEM DESCRIPTION: Enterprise COBOL Compiler terminated * * with message MSGIGYCB7104-U Internal * * error while compiling program 'XXXXX'. * * Failed assertion on * * ./CodeGenRA.cpp:120. Compilation * * terminated. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The compiler's internal state is wrong while generating instructions in above case.
Problem conclusion
The compiler's internal state is fixed while generating instructions in above case.
Temporary fix
Comments
APAR Information
APAR number
PH57091
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-09-21
Closed date
2023-11-15
Last modified date
2023-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI94489
UP23/11/22 P F311
R631 PSY UI94490
UP23/11/22 P F311
R632 PSY UI94491
UP23/11/22 P F311
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: