A fix is available
APAR status
Closed as program error.
Error description
1. A customer cancelled the IMS Connect started task and during termination CEXEXRTR was called with PSATOLD of zeroes. This is unexpected and resulted in an abend0C4. 2. In the Publisher API PC routine CEXPC01 a global variable is incremented whenever the PC routine is entered and should be decremented before the PC routine returns. The variable is decremented correctly when exiting correctly, but the ARR routine does not. The Publisher API will not end until the count is zero this may result in ICON hanging in shutdown. CEX5029I CEX Publisher API waiting for 1 PC routine(s) to end before closing
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V3.1 * **************************************************************** * PROBLEM DESCRIPTION: Two fixes for CEXEXRTR and CEXPC01 * **************************************************************** 1. A customer had cancelled the IMS Connect started task and during termination CEXEXRTR was called with PSATOLD of zeros this is unexpected and resulted in an abend S0C4. 2. In the Publisher API PC routine CEXPC01 a global variable is incremented whenever the PC routine is entered and should be decremented before the PC routine returns. The variable is decremented correctly when exiting correctly, but the ARR routine does not. The Publisher API will not end until the count is zero this may result in ICON hanging in shutdown.
Problem conclusion
1. CEXEXRTR is corrected so that if PSATOLD is zeros it returns with RC=16. 2. CEXPC01 ARR routine is updated to decrement the PC routine count.
Temporary fix
Comments
APAR Information
APAR number
PH56925
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-09-13
Closed date
2023-09-21
Last modified date
2023-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI93682
Modules/Macros
CEXAUTH0 CEXEXRTR CEXPC01 CEXROUT0 CEXSVC01 CEXTECL CEXTEOT
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R310 PSY UI93682
UP23/09/29 P F309
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]
Document Information
Modified date: