Direct links to fixes
APAR status
Closed as program error.
Error description
Connect Direct Server Adapter (CDSA) traffic is slow. Suspend queue is backlogged. CDSA creates a separate thread at startup to monitor the suspended queue. The purpose is to resume entries in the queue after the adapter is back online. CDSA attempts to shut down the thread (if it's active/still processing suspended entries) by interrupting it during the CDSA's shutdown phase. Unfortunately, the body of the thread does not respond to the interrupt message, consequently it continues to execute as long as it has work to do.
Local fix
STRTC - 521510 RW/RW Circumvention: Restart of Sterling Integrator itself is not sufficient, All CDSA adapters must be stopped and restarted while the appliction is up to clear up issue.
Problem summary
Users Affected: IBM Sterling B2B Integrator V5.2 Users Problem Description: The Connect Direct Server Adapter (CDSA) does not halt processing the suspended queue after it is disabled. Platforms Affected: All
Problem conclusion
Resolution Summary: A code fix is provided. Delivered In: 5020500_15 5020601_7 5020603_1 5020602_4
Temporary fix
Comments
APAR Information
APAR number
IT18179
Reported component name
STR B2B INTEGRA
Reported component ID
5725D0600
Reported release
525
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-11-30
Closed date
2017-01-18
Last modified date
2017-05-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR B2B INTEGRA
Fixed component ID
5725D0600
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS3JSW","label":"Sterling B2B Integrator"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.5","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: