PH54845: ABEND 0C4 IN CEXEXRTR ROUTINE UIMMST WHEN MESSAGE EXIT HAS NO DEFINITION RECORD IN THE REPOSITORY.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend0c4 at UIMST +X'34' is a new flavor of the abend fixed by
    PI14688 and PI20500. In this case the message exit having no
    exit definition causes a code path to be taken which was not
    addressed by previous fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Connect Extensions V3.1         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend 0C4 in CEXEXRTR routine UIMMST    *
    *                      when message exit has no definition     *
    *                      record in the repository.               *
    ****************************************************************
    Abend at UIMST +X'34' is a new flavour of the abend fixed by
    PI14688 and PI20500. In this case the message exit having no
    exit definition causes a code path to be taken which was not
    addressed by previous fixes.
    

Problem conclusion

  • CEXEXRTR is corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH54845

  • Reported component name

    IMS CONNECT EXT

  • Reported component ID

    5655K4800

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-05-31

  • Closed date

    2023-08-30

  • Last modified date

    2023-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI93362

Modules/Macros

  • CEXEXRTR
    

Fix information

  • Fixed component name

    IMS CONNECT EXT

  • Fixed component ID

    5655K4800

Applicable component levels

  • R310 PSY UI93362

       UP23/10/02 P F309

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88S","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date:
02 October 2023