A fix is available
APAR status
Closed as program error.
Error description
The scenario addressed in PH49378 which led to CSQIRTAG being called with a null RURE address is possible in other scenarios. 0C4-11 abend will occur as below. SVC DUMP HAS CAPTURED: REQUESTED BY JOB (jobname ) DUMP TITLE=CSQ1,ABN=0C4-00000011,U=USER1 ,C=MQ900.920.MMC -CSQMSERH,M=CSQGFRCV,LOC=CSQMLPLM.CSQMSERH+XXXXXXXX
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM MQ for z/OS Version 9 * * Release 2 Modification 0 and * * Release 3 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: An S0C4-11 abend is seen during an * * MQDISC call in an application address * * space that is connected into the Queue * * Manager. * **************************************************************** An S0C4-11 abend is seen during an MQDISC call in an application address space that is connected into the Queue Manager as part of implicit commit processing. The module CSQIRTAG is incorrectly called as part of this processing and when called in this way can cause the S0C4 abend due to not having the expected valid RURE pointer value.
Problem conclusion
The code has been corrected so that CSQIRTAG is no longer incorrectly called as part of implicit commit processing from an MQDISC api call made by an address space that is connected into the Queue Manager.
Temporary fix
Comments
APAR Information
APAR number
PH50895
Reported component name
IBM MQ Z/OS V9
Reported component ID
5655MQ900
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-11-14
Closed date
2023-08-21
Last modified date
2023-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI93254 UI93255
Modules/Macros
CSQRIPMU CSQRRSPC CSQRUA02 CSQRUC02
Fix information
Fixed component name
IBM MQ Z/OS V9
Fixed component ID
5655MQ900
Applicable component levels
Fix is available