A fix is available
APAR status
Closed as program error.
Error description
Error message IGYCB7104-U may be issued when compiling COBOL program when compiling with NUMCHECK.
Local fix
Compile with NONUMCHECK
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.x compiling * * programs with NUMCHECK that have secondary * * entry points and have data items in * * LOCAL-STORAGE that are of a type checked by * * NUMCHECK and that are referenced in the * * PROCEDURE DIVISION in a location that is * * reachable from one or more secondary entry * * points. * **************************************************************** * PROBLEM DESCRIPTION: Enterprise COBOL Compiler terminated * * with message MSGIGYCB7104-U Internal * * error while compiling program XXXXXXXX. * * Failed assertion on * * ilgen/NSEPChecker.cpp:360. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** While finding the addresses of data items relative to the start of a secondary entry point, the compiler was abending when checking data items that are both in LOCAL-STORAGE and are checked by NUMCHECK.
Problem conclusion
The compiler no longer abends when finding the addresses of data items relative to the start of a secondary entry point for items that are both in LOCAL-STORAGE and are checked by NUMCHECK.
Temporary fix
Comments
APAR Information
APAR number
PH56204
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-08-03
Closed date
2023-08-25
Last modified date
2023-09-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJBLD IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UI93309
UP23/08/31 P F308
R641 PSY UI93310
UP23/08/31 P F308
R642 PSY UI93311
UP23/08/31 P F308
R64H PSY UI93312
UP23/08/31 P F308
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: