PH55926: AFTER HAVING TRANSFERRED AN UPGRADE PACKAGE TO AN ACCELERATOR THE VERIFICATION PROCESS CAN FACE A TIMEOUT (msg AQT20107E)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • The upgrade process of the Accelerator on IIAS starts with the
    download of the upgrade packages from IBM FixCentral and
    comprises a couple of other steps, one of which is the transfer
    of the package to the transfer folder on the accelerator. The
    step to copy the package to the transfer folder is immediately
    followed by the validation of the package and by a preliminary
    hardware-check.
    
    With the upgrade to Accelerator maintenance level 7.5.10 or
    later, the hardware-check includes a verification of the Flash
    Storage Nodes (FSN) which leads to a longer runtime.
    The accelerator verifies whether the hardware-check will be done
    within the limit having been defined by parameter
    APUPGRADE_COMMAND_EXECUTION_TIMEOUT in configuration file
    dwaserver.conf. The default value is 15 minutes (or 900
    seconds).
    If this limit will be exceeded, the message
    "AQT20107E - The component responsible for software updates did
    not finish the execution of the command 'apupgrade
    --preliminary-check' within the timeout period of 900 seconds."
    will be raised. In parallel, the upgrade package will be be
    removed from the transfer folder on the accelerator.
    
    With Accelerator maintenance level 7.5.12 or later, the default
    value configuration parameter
    APUPGRADE_COMMAND_EXECUTION_TIMEOUT will be set to 30 minutes.
    Attention: this new default value will only influence upgrades
    to maintenance levels following 7.5.12.
    Therefore we strongly recommend to have IBM support change
    configuration parameter APUPGRADE_COMMAND_EXECUTION_TIMEOUT to a
    value of 30 minutes at any time PRIOR to transferring an upgrade
    package to the accelerator. This change does not require an
    outage and will become valid instantly.
    
    Additional keywords:
    TS012855291 TS008761266 TS008126545 upgrade AQT20107E DT225503
    timeout package removal APUPGRADE_COMMAND_EXECUTION_TIMEOUT
    

Local fix

  • If you are or were affected by a timeout during the transfer of
    an upgrade package to the accelerator, please contact IBM
    support. In a remote maintenance session the support engineer
    will increase the value of dwa configuration parameter
    APUPGRADE_COMMAND_EXECUTION_TIMEOUT. In such a situation we
    recommend to double the parameter's default value of 900
    meaning sseconds which equals to 15 minutes) by setting
    "APUPGRADE_COMMAND_EXECUTION_TIMEOUT = 30min" in
    dwa.server.conf before redoing the transfer.
    

Problem summary

  • Problem Summary:
    See Error Description.
    
    Users Affected:
    Administrators of accelerators on IIAS (especially when
    upgrading multi-rack systems).
    
    Problem Scenario:
    The transfer of an upgrade package to the transfer folder on the
    accelerator includes a preliminary hardware-check. The default
    timeout for this check is 900 seconds which equals to 15
    minutes. If the check requires requires more than 900 seconds,
    the transferred upgrade package will be deleted from the
    transfer folder on the accelerator. Subsequently, another
    transfer of the upgrade package is required.
    
    Problem Symptoms:
    Looking at the files apupgrade.log and apupgrade.log.tracelog it
    can be seen that the time interval between the command
    "apupgrade --preliminary-check ..." and the timeout message
    exceeds 900 seconds. Although the preliminary hardware-check is
    continued in the apupgrade.log, the accelerator receives a
    timeout. He does no longer wait for the successful execution of
    the check and removes the upgrade package from the transfer
    folder.
    

Problem conclusion

  • With Accelerator maintenance level 7.5.12 or later, the default
    value configuration parameter
    APUPGRADE_COMMAND_EXECUTION_TIMEOUT will be set to 30 minutes.
    Attention: this new default value will only influence upgrades
    to Accelerator maintenance levels following 7.5.12.
    
    If you are or were affected by a timeout (message AQT20107E)
    during the transfer of an upgrade package to the accelerator,
    please contact IBM support. In a remote maintenance session the
    support engineer will increase the value of the configuration
    parameter APUPGRADE_COMMAND_EXECUTION_TIMEOUT. In such a
    situation we recommend to double the parameter's default value
    of 900 (meaning seconds which equals to 15 minutes) by setting
    "APUPGRADE_COMMAND_EXECUTION_TIMEOUT = 30min" in dwa.server.conf
    before re-doing the transfer.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH55926

  • Reported component name

    ANYTCS ACCLTR Z

  • Reported component ID

    5697DA700

  • Reported release

    750

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-07-21

  • Closed date

    2024-03-18

  • Last modified date

    2024-03-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"750"}]

Document Information

Modified date:
18 March 2024