PH55881: An empty JAVA-CALLABLE procedure division causes a compiler loop

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If you're trying out a JAVA-CALLABLE build with no code in the
    procedure division, something like this:
    
        ...
        LINKAGE SECTION.
        77 PARM PIC ...
        >>JAVA-CALLABLE
        PROCEDURE DIVISION USING PARM.
    
    then the compiler will loop after having produced only the
    "Options in effect" report.
    

Local fix

  • Provide some procedure division content, for example a DISPLAY
    statement.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling      *
    *                 programs that use the JAVA-CALLABLE          *
    *                 directive and have procedure divisions that  *
    *                 are empty.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler enters an infinite loop and    *
    *                      fails to                                *
    *                      complete compilation.                   *
    ****************************************************************
    * RECOMMENDATION: Install the IBM-provided PTF                 *
    ****************************************************************
    The compiler was not properly handling programs
    with an empty procedure division when the
    JAVA-CALLABLE directive was present.
    

Problem conclusion

  • The compiler was updated to properly
    process empty procedure division programs
    that have the JAVA-CALLABLE directive.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH55881

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-07-19

  • Closed date

    2023-08-25

  • Last modified date

    2023-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCJBLD IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2  IGYCOSCN
    IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN
    IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5
    IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE
    IGYMSGK  IGYMSGT  IGYQCBE  IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6
    IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R640 PSY UI93309

       UP23/08/31 P F308

  • R641 PSY UI93310

       UP23/08/31 P F308

  • R642 PSY UI93311

       UP23/08/31 P F308

  • R64H PSY UI93312

       UP23/08/31 P F308

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
01 September 2023