APAR status
Closed as program error.
Error description
Connecting to the TEPS using the command 'tacmd tepslogin' fails returning the error messages: KUICTL099E The tepsLogin command failed because an unexpected error occurred. Please consult the /opt/IBM/ITM/logs/TepsLoginCLI_0.log log file to determine the cause of the error. An unexpected system error occurred while executing the tepsLogin command. The TepsLoginCLI_0.log file may provide more information about this error. If you require further assistance resolving the error, contact IBM Software Support.
Local fix
Workaround: For Unix and Linux systems add the following text line to the Tivoli Enterprise Portal Server's configuration file $CANDLEHOME/config/cq.ini (Unix/Linux). KFW_ORB_ENABLED_PROTOCOLS=TLS_Version_1_2_Only For Windows systems add the following text line to the TEPS' configuration by selecting Advanced->Edit ENV File and then adding the following KFW_ORB_ENABLED_PROTOCOLS=TLS_Version_1_2_Only
Problem summary
TEPSLOGIN FAILS WITH ERROR KUICTL099E
Problem conclusion
Fix delivered in SP13
Temporary fix
Comments
APAR Information
APAR number
IJ40895
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-06-28
Closed date
2023-06-02
Last modified date
2023-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSZ8F3","label":"IBM Tivoli Monitoring V6"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630"}]
Document Information
Modified date:
03 June 2023