IBM Support

BMXAA4211E - Database error number -302 has occurred when operating on INBOUNDCOMMCFG, when you save Listener Definition

How To


Summary

When trying to save the E-mail Listener Definition, you are not able to proceed and a dialog opens with the error BMXAA4211E, it's required to increase the length of oauth attributes in INBOUNDCOMMCFG table.

Steps

1. Go to System Configuration, Platform Configuration, then Database Configuration.
 
2. Search for INBOUNDCOMMCFG object.
 
3. Open attributes tab and search for the attributes OAUTHCLIENTID, OAUTHCLIENTSECRET, OAUTHACCESSTOKEN, and OAUTHREFRESHTOKEN.
image-20230517114158-1
4. Define the length values as 2,000 and if the error persists, define as 3,000.
5. Apply Configuration Changes.

Document Location

Worldwide

[{"Type":"MASTER","Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"ARM Category":[{"code":"a8m50000000CbU1AAK","label":"System Administration-\u003EE-Mail Listeners"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.6.1"}]