IBM Support

PH54547: INSPECT CONVERTING STATEMENT, RESULT IS NOT CORRECT WITH COBOL V6.4 BUT CORRECT WITH V6.3

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • INSPECT CONVERTING statement, result is not correct with COBOL
    v6.4 but correct with v6.3
    
    ADDITIONAL SYMPTOMS:
    Instead of converting single characters from literal1 to the
    corresponding characters in literal2, the compiled program
    searched for literal1 and replaced the entire string with
    identifier2.
    

Local fix

  • BYPASS/CIRCUMVENTION:
    None
    
    RECOVERY ACTION:
    Apply PTF
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling      *
    *                 programs with INPSECT A CONVERTING B TO C    *
    *                 where B is either a literal or is            *
    *                 determined to be a constant value by the     *
    *                 optimizer, C is a data item that is not      *
    *                 determined to be a constant value by the     *
    *                 optimizer, and the lengths of B and C are    *
    *                 greater than 1 if the program is compiled    *
    *                 at ARCH(10) or greater than 8 if the         *
    *                 program is compiled at ARCH(11+).            *
    ****************************************************************
    * PROBLEM DESCRIPTION: Instead of converting single            *
    *                      characters in A that are found in B to  *
    *                      the corresponding characters in C, the  *
    *                      compiled program searched for           *
    *                      occurrences of the entire contents of   *
    *                      B in A and replaced them with C.        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    The compiler incorrectly determined it was safe to generate
    instructions for the INSPECT CONVERTING statement, rather than
    call the COBOL Runtime to do the work.
    

Problem conclusion

  • The compiler was fixed to correctly determine it is unsafe to
    generate instructions for this particular INSPECT CONVERTING
    statement, and it now correctly calls the COBOL Runtime instead.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH54547

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-05-16

  • Closed date

    2023-06-19

  • Last modified date

    2023-09-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH56952

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCJBLD IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN
    IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD
    IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8
    IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK
    IGYMSGT  IGYQCBE  IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R640 PSY UI92327

       UP23/06/28 P F306

  • R641 PSY UI92328

       UP23/06/28 P F306

  • R642 PSY UI92329

       UP23/06/28 P F306

  • R64H PSY UI92330

       UP23/06/28 P F306

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: