IBM Support

PH54376: CHANGE TRACKER STARTED TASK GETS S878-10 ABEND

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The Change Tracker started task abends with the following
    messages:
    
    IEA705I ERROR DURING GETMAIN SYS CODE = 80A-10 CYGSTC CYGSTC 40
    IEA705I 00F8A280 00ACBB80 00ACBB80 00001200 0001B368
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM z/OS Change Tracker.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. The started task terminates with     *
    *                         GETMAIN abend 80A-10                 *
    *                      2. Abend 0C4 when running the           *
    *                         SURVEILLANCE command against a data  *
    *                         set with no members.                 *
    *                      3. Abend 0C4 when running the           *
    *                         SURVEILLANCE command against a data  *
    *                         set that is protected with the       *
    *                         QUICKMODE=YES option.                *
    *                      4. Abend 0C4 in CYGTKEXT on STC         *
    *                         shutdown.                            *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    1.The started task terminates with GETMAIN abend 80A-10 when
      there is heavy open/close activity on a protected data set.
      The following messages appear in the started task log:
    
    IEA705I ERROR DURING GETMAIN SYS CODE = 80A-10 CYGSTC CYGSTC 40
    IEA705I 00F8A280 00ACBB80 00ACBB80 00001200 0001B368
    2. Abend 0C4 when running the SURVEILLANCE command against a
       data set with no members.
    3. Abend 0C4 when running the SURVEILLANCE command against a
       data set that is protected with the QUICKMODE=YES option.
    4. Abend 0C4 in CYGTKEXT on STC shutdown.
    

Problem conclusion

  • 1. The amount of storage freed on close for a directory area was
       less than the amount originally obtained, causing the started
       task to run out of storage after many close operations. The
       amount of storage freed is now equal to that obtained.
    2. Incorrect handling of empty data sets in SURVEILLANCE is
       fixed.
    3. Incorrect handling of QUICKMODE data sets in SURVEILLANCE is
       fixed.
    4. A storage area was being prematurely freed. The freeing of
       the area is moved to a later stage in the shutdown.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH54376

  • Reported component name

    Z/OS CHANGE TRA

  • Reported component ID

    5752SCCYG

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-05-08

  • Closed date

    2023-06-19

  • Last modified date

    2023-08-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI92339

Modules/Macros

  • CYGCOMM  CYGMEML  CYGMOD   CYGPDSDR CYGSYSI  CYGSYSO
    

Fix information

  • Fixed component name

    Z/OS CHANGE TRA

  • Fixed component ID

    5752SCCYG

Applicable component levels

  • R100 PSY UI92339

       UP23/07/07 P F307

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"100"}]

Document Information

Modified date: