IBM Support

PH50418: AUDIT LOG SHOWS CONTENTRETURN="0" FOR A CARD WHERE WE SHOULD HAVE CONTENTRETURN="21"

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • It may be noted that IBM Transformation Extender (ITX) maps that
    end creating invalid output data do not generate a correct
    return on the contentreturn of the audit log for the appropriate
    output card.
    
    When the <ExecutionSummary> shows mapreturn="14" and
    <Message>One or more outputs was invalid</Message>, at least one
    of the output cards should show the 14 code in content return.
    
    For example:
    
    <outputstatus   card="1"   bytes="12"   adapterreturn="0"
    contentreturn="0"/>
    <outputstatus   card="2"   bytes="34"   adapterreturn="0"
    contentreturn="14"/>
    <outputstatus   card="3"   bytes="56"   adapterreturn="0"
    contentreturn="0"/>
    
    Instead all output cards show 0 in content return:
    
    <outputstatus   card="1"   bytes="12"   adapterreturn="0"
    contentreturn="0"/>
    <outputstatus   card="2"   bytes="34"   adapterreturn="0"
    contentreturn="0"/>
    <outputstatus   card="3"   bytes="56"   adapterreturn="0"
    contentreturn="0"/>
    

Local fix

  • ITXCQ - ITX00061643
    PB / PB
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender users using output validation and
    audit.
    
    Problem Description:
    Audit log shows contentreturn="0" for a card where we should
    have contentreturn="14"
    
    Platforms Affected:
    All
    

Problem conclusion

  • Correct processing of "contentreturn" field in audit when
    message "One or more outputs was invalid" is produced.
    Previously it was always zero. Now it has the correct value of
    14.
    
    Applies to:
    9.0.0.5, 10.0.0.0, 10.0.3.1 10.1.1.1, 10.1.2.0
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
    check the IBM Transformation Extender Release Notes page:
    https://www.ibm.com/support/docview.wss?uid=swg27008337
    
    If the service pack or product release is available, download it
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a case:
    https://www.ibm.com/mysupport/
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH50418

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-10-26

  • Closed date

    2023-03-07

  • Last modified date

    2023-04-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels