A fix is available
APAR status
Closed as program error.
Error description
Dynamic Test Runner internal defects and enhancements
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: 01.All ZUnit users that have mult-test test * * cases aginst a main program * * 02.All DTR users making use of IMS GSAM GN * * recording * * 03.All DTR users making use of "Save all * * result data" option * * 04.All DTR users making use of IMS recording * * with the COBOL DYNAM option * * 05.All ZUnit users * * 06.CICS admin & sysprog * * 07.All DTR users Testing PL/I programs after * * the change set for 110015 * **************************************************************** * PROBLEM DESCRIPTION: 01.ZUnit multi-test test case where the * * 2nd-Nth tests use different * * recording data than the first * * against the same program. The 1st * * test would pass, the remaining tests * * would fail. * * 02.ZUNIT RECORDING DOES NOT RECORD GSAM * * READS FOR AIBTDLI * * 03.Zunit - Job results in RC 16 when * * "Save all result data" is checked in * * the 'Run Test Case' * * 04.CBLTDLI GN (getNext) does not return * * any data in zUnit * * 05.Enhancement - ZUnit 16.0.2 requires * * access to the record count fields in * * BZU_TERM routine * * 06.Enhancement to provide sample * * LIBRARY definition * * 07.BZUP249W issued for all PL/I P2P * * calls on replay * **************************************************************** when the 2nd-Nth tests use different recording data than the first against the same program. The 1st test would pass, the remaining tests would fail. This no longer occurs as the available, unused records from the 1st test are cleared before starting the 2nd test (so it reads and uses only its own set of records from the recording data set). 02.ZUNIT RECORDING DOES NOT RECORD GSAM READS FOR AIBTDLI 03.Zunit - Job results in RC 16 when "Save all result data" is checked in the 'Run Test Case' 04.CBLTDLI GN (getNext) does not return any data in zUnit 05.Enhancement - ZUnit 16.0.2 requires access to the record count fields in BZU_TERM routine. The new field was added to CALL statements for all user exit points to allow them access to the control block. All ZUnit users are affected by this change as it adds a new control block (AZ-INFO-BLOCK) to all of the user exit points generated in the test case program. The users, however, will not see any impact if the correct version of ZUnit is used with the correct version of the Dynamic Test Runner. 06.Enhancement to provide a sample CSD LIBRARY definition for Dynamic Test Runner, which avoids the need to update the CICS region JCL. 07.BZUP249W issued for all PL/I P2P calls on replay. Logic to generate BZUP249W message did not account for PL/I linkage.
Problem conclusion
01.Update provided. 02.Modified length field used in moving returned data to recording file and changed the internal configuration table to show the data sent on input rather than on output. 03.Replaced check for flag signifying the presence of the BZUNEXT DD statement with a macro call to search for it independently. 04.The issue was caused by the LE program name extract bringing back a COBOL runtime name instead of the program under test, this caused the exit name table to be improperly built and causing a mismatch between it and the zUnit exit point names. Converted program name filter into a called routine so that it could be used against the LE program name extracts as well. Now when a program prefix to be ignored is returned, the program name under test will be used instead. 05.Adds a new control block (AZ-INFO-BLOCK) to all of the user exit points generated in the test case program. The exit points will have access, but may not use, the control block fields. 06.Sample definition provided. 07.Added flag to indicate program language and bypass the message generation for PL/I.
Temporary fix
Comments
APAR Information
APAR number
PH53476
Reported component name
DYNAMIC TEST RU
Reported component ID
5724T0763
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-03-23
Closed date
2023-06-12
Last modified date
2023-07-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI92203
Modules/Macros
BZU1SMPE BZU2EXEC BZU2LAYR BZU2THIN BZU2TLYR BZU3ALOC BZU6DDEF BZUACAF@ BZUACP BZUADSMF BZUAEIN@ BZUAETR@ BZUAINIT BZUAIP2 BZUAIPI BZUAIPS BZUAIPX BZUALLOC BZUAPIPI BZUAPRC2 BZUAPRCA BZUAPRCD BZUAPRCX BZUAPRH@ BZUAPRS@ BZUARGID BZUARRS@ BZUARSMF BZUARST0 BZUARST1 BZUARST2 BZUARST3 BZUARST4 BZUARST5 BZUARST6 BZUARST7 BZUARST8 BZUARST9 BZUASSRT BZUASTB0 BZUASTB1 BZUASTB2 BZUASTB3 BZUASTB4 BZUASTB5 BZUASTB6 BZUASTB7 BZUASTB8 BZUASTB9 BZUASTC0 BZUASTC1 BZUASTC2 BZUASTC3 BZUASTC4 BZUASTC5 BZUASTC6 BZUASTC7 BZUASTC8 BZUASTC9 BZUASTMD BZUASTMP BZUASTUB BZUASTUC BZUAVRDT BZUBATCH BZUBCON@ BZUBCP BZUBDSC@ BZUBSRV@ BZUCBCBL BZUCBPL1 BZUCCDFN BZUCCINT BZUCCOLL BZUCDEFN BZUCF410 BZUCF420 BZUCF510 BZUCF520 BZUCF530 BZUCF540 BZUCF550 BZUCF560 BZUCF610 BZUCI410 BZUCI420 BZUCI510 BZUCI520 BZUCI530 BZUCI540 BZUCI550 BZUCI560 BZUCI610 BZUCICPT BZUCICSA BZUCICSL BZUCICSN BZUCICSS BZUCICST BZUCICSW BZUCICSX BZUCIDFN BZUCIDRI BZUCIDRP BZUCIDRR BZUCIDRS BZUCIDRT BZUCO410 BZUCO420 BZUCO510 BZUCO520 BZUCO530 BZUCO540 BZUCO550 BZUCO560 BZUCO610 BZUCODES BZUCPLTI BZUCPLTS BZUCPLTT BZUCRECS BZUCRECT BZUCSD BZUCSTUB BZUDB2CA BZUDB2CP BZUDB2CV BZUDB2PA BZUDB2PP BZUDB2PV BZUDB2ST BZUDCP BZUDLAYR BZUDTHIN BZUDTLYR BZUDYNAL BZUECP BZUEIBPL BZUESPIE BZUESPR@ BZUESTAE BZUGETEP BZUGTARG BZUGTMEM BZUHFIO@ BZUHFIOH BZUHFIOP BZUHPRN@ BZUII410 BZUII420 BZUII510 BZUII520 BZUII530 BZUII540 BZUII550 BZUII560 BZUII610 BZUIMSSB BZUIMSSE BZUIMSSF BZUIMSTR BZUIMSVN BZUIMSVR BZUINCL BZUIO410 BZUIO420 BZUIO510 BZUIO520 BZUIO530 BZUIO540 BZUIO550 BZUIO560 BZUIO610 BZUISVI0 BZUITERC BZUITERP BZUJFIOH BZUJFIOP BZUKFIO@ BZUKFIOH BZUKFIOP BZULCEE BZULDB2 BZULEOPT BZULFIOH BZULFIOP BZULIMS BZULLE BZULMQ BZUMCP BZUMETA BZUMSGEN BZUPBCP BZUPBMP BZUPDB2 BZUPDCP BZUPDLI BZUPECP BZUPLAY BZUPMCP BZUPPLAY BZUPRH00 BZUPRH0@ BZURCP BZURI410 BZURI420 BZURI510 BZURI520 BZURI530 BZURI540 BZURI550 BZURI560 BZURI610 BZURO410 BZURO420 BZURO510 BZURO520 BZURO530 BZURO540 BZURO550 BZURO560 BZURO610 BZURPLAY BZURRCP BZURTCP BZURUN BZUSCFG BZUSCP BZUSETUP BZUSLAYR BZUSTLYR BZUSUDSN BZUSYSIN BZUTCP BZUTRACE BZUUFIOH BZUUFIOP BZUUMODC BZUUMODD BZUUMODI BZUUMODL BZUVERS BZUVFIOH BZUVFIOP BZUVRM
Fix information
Fixed component name
DYNAMIC TEST RU
Fixed component ID
5724T0763
Applicable component levels
R100 PSY UI92203
UP23/06/20 P F306
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"100"}]
Document Information
Modified date:
03 July 2023