A fix is available
APAR status
Closed as new function.
Error description
In response to customer requirements, the *VMEVENT Enhancements line item will deliver new and enhanced event records. New event records are generated to provide data associated with virtual machine console disconnection and reconnection. Logon event records are extended to identify the logon-by user (if any) and to identify the terminal connection. The logoff-timeout-started and logoff-timeout-service event records are enhanced to report large timeout intervals correctly, by appending a 32-bit unsigned interval value to the existing message format. Redundant runnable (Class 0 Type 5) events are eliminated. The runnable event is now reported only when the virtual machine is leaving a non-runnable state.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of the *VMEVENT CP System Service * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** *VMEVENT Enhancements will deliver new and enhanced event records. New events are added for machine console reconnection (Class 0, Type 28) and disconnection (Class 0, Type 29). The runnable event (Class 0, Type 5) is modified to only report on a state change. The logoff-timeout-started (Class 0, Type 3) and logoff-timeout-service (Class 1, Type 3) event records are enhanced to report large timeout intervals correctly, by appending a 32-bit unsigned interval value to the existing message format. The logon event (Class 0, Type 0) is modified to include logon-by and terminal information in the message.
Problem conclusion
Temporary fix
Comments
Publication Changes: z/VM: CP Programming Services (SC24-6272-73) z/VM: General Information (GC24-6286-73) z/VM: Migration Guide (GC24-6294-73) Changes were made to *VMEVENT code to accommodate the additional events, as well as modify the payloads of the existing events. Logon processing was modified to trigger the reconnect event, and disconnect processing was modified to trigger the disconnect event.
APAR Information
APAR number
VM66679
Reported component name
VM CP CP
Reported component ID
568411202
Reported release
730
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2023-03-17
Closed date
2023-06-09
Last modified date
2024-04-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UM90293
Modules/Macros
HCPEQUAT HCPIIO HCPLGO HCPSZK HCPSZL HCPUSO HCPVMDBK HCPVME HCWAI8 HCWA12
SC24627273 | GC24628673 | GC24629473 |
Fix information
Fixed component name
VM CP CP
Fixed component ID
568411202
Applicable component levels
R730 PSY UM90293
UP23/06/13 P 2401
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG27M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"730"}]
Document Information
Modified date: