IBM Support

PH47563: CSQX112E CSQXDISP DISPATCHER PROCESS ERROR CSQFSAMG +00B7A 23/03/20 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MQ Development finds that a hostname lookup failed for a
    specified LOCLADDR while the associated channel was
    attempting to start. This caused the CHIN to build a CSQX235E
    message to report this, and the 0C4 abend occurred while
    building this message. The length of the first line of the
    message was long enough that it needed to be split over 2
    lines, and it's in this processing where the problem lies. An
    invalid combination of flags in the CHINIT message control
    block (xMcb) results in a message LLZZ being interpreted as a
    buffer address. This problem was introduced by PTF UI68821.
    

Local fix

  • Ensure LOCLADDR value is resolvable.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM MQ for z/OS Version 9       *
    *                 Release 1 Modification 0 and                 *
    *                 Release 2 Modification 0 and                 *
    *                 Release 3 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Starting a channel with an invalid      *
    *                      LOCLADDR value thats length is greater  *
    *                      than 25 characters causes errors.       *
    *                                                              *
    *                      At V910 an S0C4-00000011 abend in seen  *
    *                      in CSQFSAMG in the channel initiator    *
    *                      address space.                          *
    *                                                              *
    *                      At V920 & V930 the message CSQX235E     *
    *                      is incorrectly formatted and the        *
    *                      LOCLADDR value printed with the message *
    *                      is incorrectly truncated.               *
    ****************************************************************
    When starting a channel with an invalid LOCLADDR value thats
    length is greater than 25 characters, errors are seen as part of
    printing the message CSQX235E in the channel initiators joblogs
    to report the invalid LOCLADDR value.
    
    At V910 an S0C4-00000011 abend in seen in CSQFSAMG in the
    channel initiator address space caused by a regression
    introduced by PTF UI68821.
    
    At V920 & V930 the message CSQX235E is incorrectly formatted as
    the LOCLADDR value printed with the message fails to be moved to
    a new line and is thus incorrectly truncated.
    

Problem conclusion

  • At V910 the regression introduced by PTF UI68821 has been
    corrected so that the CSQX235E message is correctly printed to
    the channel initiators joblogs and the S0C4 abend is not issued.
    
    At V920 & V930 the formatter processing message CSQX235E has
    been corrected to utilise multiple lines to display the LOCLADDR
    value if its length is greater than 25 characters long and will
    not be truncated.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH47563

  • Reported component name

    IBM MQ Z/OS V9

  • Reported component ID

    5655MQ900

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-28

  • Closed date

    2023-03-20

  • Last modified date

    2023-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI91039 UI91040 UI91041

Modules/Macros

  • CSQFXLAT CSQMCNAC CSQUMSG  CSQXCCCX CSQXCCIS CSQXGINI CSQXMSG
    CSQXRPLY
    

Fix information

  • Fixed component name

    IBM MQ Z/OS V9

  • Fixed component ID

    5655MQ900

Applicable component levels

  • R100 PSY UI91041

       UP23/04/08 P F304 {

  • R200 PSY UI91040

       UP23/04/07 P F304 {

  • R300 PSY UI91039

       UP23/04/07 P F304 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"100","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: