IBM Support

IT43376: STORAGE INSIGHTS DOESN'T DISPLAY ERROR WHEN THE PORT 22 IS NOT REACHABLE DURING AN ADD SWITCH

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • The documentation indicates The data collector that is assigned
    to a Brocade switch must have SSH access on port 22 to collect
    metadata.
    https://www.ibm.com/docs/en/storage-insights?topic=fabrics-plan
    ning-brocade-switches
    
    Storage Insights should display an error message if the port 22
    is not reachable when adding a Brocade Switch to inform the user
    about the failure.
    

Local fix

  • Check to ensure the required ports are enabled and active:
    
    To connect to and collect metadata about Brocade switches
    and fabrics, the following ports are used:
    
     -  22 for SSH
     -  80 for HTTP
     -  443 for HTTPS
    
    The data collector that is assigned to a Brocade switch must
    have SSH access on port 22 to collect metadata.
    In environments with multiple data collectors, a data collector
    without SSH access on port 22 might be assigned to a switch
    when it's being added for monitoring. In that case, adding the
    switch will fail, even if other data collectors have SSH access
    on port 22.
    
    To help resolve the problem, enable SSH access on port 22
    to the switch on all your data collectors. Then, try to add the
    switch again.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Storage Insights users adding Brocade switch to be       *
    * monitored                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The Storage Insights documentation indicates that the        *
    * data collector which is assigned to a Brocade switch         *
    * must have SSH access on port 22 to collect metadata.         *
    *                                                              *
    * https://www.ibm.com/docs/en/storage-insights?topic=fabrics-p *
    * lan                                                          *
    * ning-brocade-switches                                        *
    *                                                              *
    * Storage Insights should display an error message if          *
    * port 22 is not reachable when adding a Brocade switch        *
    * to inform the user about the failure.                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Storage Insights 2Q23   [ 54X-IBM-SI ]
    ( release target 2Q 2023 / June )
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT43376

  • Reported component name

    STORAGE INSIGHT

  • Reported component ID

    5608TPCSI

  • Reported release

    54X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-17

  • Closed date

    2023-05-23

  • Last modified date

    2023-05-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STORAGE INSIGHT

  • Fixed component ID

    5608TPCSI

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSYS7R","label":"IBM Spectrum Control Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"54X"}]

Document Information

Modified date:
23 May 2023