IJ45274: VSCSI CLIENT IO HANG MAY OCCUR WHEN VSCSI_PATH_TO IS SET. APPLIES TO AIX 7300-01

 

APAR status

  • Closed as program error.

Error description

  • ****************************************************************
    * USERS AFFECTED:
    * Systems running the 7300-01 Technology Level with
    * any of the following filesets at or between the given levels:
    * MIN          MAX          FILESET
    * 7.3.1.0      7.3.1.0      devices.vdevice.IBM.v-scsi.rte
    ****************************************************************
    * PROBLEM DESCRIPTION:
    * IO hang may occur on vscsi client when vscsi_path_to attribute
    * is set on the vscsi adapter and the active VIOS serving the
    * client is halted immediately.
    ****************************************************************
    * RECOMMENDATION:
    * Update to AIX 7300-01-02-2320 or later.
    ****************************************************************
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:
    * Systems running the 7300-01 Technology Level with
    * any of the following filesets at or between the given levels:
    * MIN          MAX          FILESET
    * 7.3.1.0      7.3.1.0      devices.vdevice.IBM.v-scsi.rte
    ****************************************************************
    * PROBLEM DESCRIPTION:
    * IO hang may occur on vscsi client when vscsi_path_to attribute
    * is set on the vscsi adapter and the active VIOS serving the
    * client is halted immediately.
    ****************************************************************
    * RECOMMENDATION:
    * Update to AIX 7300-01-02-2320 or later.
    ****************************************************************
    

Problem conclusion

  • Indicate command failure to the caller (disk driver)
    irrespective of whether vscsi_path_to is set or not.
    

Temporary fix

Comments

  • 7200-05 - use AIX APAR IJ45263
    7300-01 - use AIX APAR IJ45274
    

APAR Information

  • APAR number

    IJ45274

  • Reported component name

    AIX V7.3

  • Reported component ID

    5765CD300

  • Reported release

    730

  • Status

    CLOSED PER

  • HIPER

    NoHIPER

  • Submitted date

    2023-02-07

  • Closed date

    2023-02-07

  • Last modified date

    2023-11-13

  • APAR is sysrouted FROM one or more of the following:

    IJ45262

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.3

  • Fixed component ID

    5765CD300

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11T","label":"AIX 7.3 HIPERS- APARs and Fixes"},"Platform":[{"code":"PF053","label":"Power Systems"}],"Version":"730","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date: