IBM Support

PH52283: DO NOT ALLOW TO START A SECOND HLO STC WITH SAME SSID AS PRIMARY.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a Loader started task is running and a second Loader
    started task is started with same DB2_SSID as primary and if
    this SSID is not listed in the started task policy then we now
    have more than one started task up and running with the same
    primary and causing Loader batch job hangs.
    With this APAR: When there is a Loader started task running, do
    not allow a second Loader started task to be started on the same
    LPAR with the same DB2_SSID (as primary) specified on the
    options file of the Loader started task. The second Loader
    started task will terminate with the following message:
    HLOS0241E........DSNUTILB interception for DB2 SSID=<ssid> is
    currently primary for ID=<HLO ID>
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Do not allow to start a second HLO      *
    *                      STC with same SSID as primary.          *
    ****************************************************************
    When a Loader started task is running and a second Loader
    started task is started with same DB2_SSID as primary and
    if this SSID is not listed in the started task policy then
    we now have more that one started task up and running with
    the same primary and causing Loader batch job hangs.
    
    With this APAR:
    When there is a Loader started task running, do not allow a
    second Loader started task to be started on the same LPAR
    with the same DB2_SSID (as primary) specified on the options
    file of the Loader started task. The second Loader started
    task will terminate with the following message:
    HLOS0241E........DSNUTILB interception for DB2 SSID=<ssid>
    is currently primary for ID=<HLO ID>
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH52283

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-01-31

  • Closed date

    2023-02-28

  • Last modified date

    2023-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • HLOADDTB HLOMSGEN HLOPIPE  HLOSINIT HLOSPLCY HLOUHAL1 HLOUHMON
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R210 PSY UI90783

       UP23/03/05 P F303

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
03 April 2023