When the Locale is a language with decimal separator comma, a meter reading with decimal value ignores the decimal separator if language is English or cannot be saved if the language is one that has comma as decimal separator. STEPS TO REPRODUCE: 1. In Maximo click Profile > Default Information and select: a. Language: EN b. Locale: de_DE c. Log out and log in 2. Open the Assets application and search an asset with a CONTINUOUS meter: 11430, meter RUNHOURS, Last Reading: e.g., 5471 3. Open the Work Order Tracking application and click to create a new work order a. Description: WO meter reading b. Asset: 11430 c. Save d. Click Take Ownership 4. Open the Work Execution work center 5. Open the details for the work order just created 6. Scroll to asset meter reading 7. Click to enter a new meter reading: it is only possible to enter 1.5 not 1,5 8. Select Delta, then Save the decimal separator is ignored, the new value of the meter is 5.486 (5471+15) 9. In an environment with a second language having decimal separator comma, in Maximo click Profile > Default Information and select: a. Language: e.g., FR b. Locale: fr_FR 10. Repeat the steps 2-7 11. Select Delta, then Save an error message is displayed requesting a value with decimal valid RESULT: Meter reading is either incorrect or cannot be entered EXPECTED RESULT: It should be possible to enter meter reading REPORTED IN VERSION: Tivoli's process automation engine 7.6.1.1
Local fix
Problem summary
**************************************************************** * PROBLEM DESCRIPTION: * * IN WORK EXECUTION WORK CENTER METER READING WITH A DECIMAL * * VALUE CANNOT BE ENTERED IF THE DECIMAL SEPARATOR IS COMMA * ****************************************************************
Problem conclusion
The fix for this APAR will be included in a future release
Temporary fix
Comments
APAR Information
APAR number
IJ44901
Reported component name
MAXIMO ASST MGM
Reported component ID
5724R46AM
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-01-10
Closed date
2023-01-24
Last modified date
2023-01-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO ASST MGM
Fixed component ID
5724R46AM