Error description

  • CSD file compile crashes on AD 602
    

Local fix

  • n/a
    

Problem summary

  • CSD Compiler - When running the csd compiler on a project set up
     on DB2 LUW, a database error is thrown and the compiler fails.
    

Problem conclusion

  • The client's source files contain programs and transactions
    whose names contain a £ character which is represented on 2
    bytes in UTF-8. Because our DB2 database is UTF-8 encoded, the
    program/transaction name exceeds the limit set to the
    corresponding field in the table.
    Fixed by increasing the limit of the program name and
    transaction  name fields in our DB. Also client's files need to
    be ANSI encoded in order to be processed correctly.
    Fixed for 6.1.2
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH51435

  • Reported component name

    AD MAINFRAME

  • Reported component ID

    5737B1610

  • Reported release

    602

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-12-13

  • Closed date

    2023-07-30

  • Last modified date

    2023-07-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AD MAINFRAME

  • Fixed component ID

    5737B1610

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRR9Q","label":"IBM Application Discovery"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"602","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: