IBM Support

IJ44238: 7612 - RADIO BUTTON GROUP CONTROL TEXT ALIGNMENT IS LEFT BUT THE HEADER IS NOT JUSTIFIED TO THE LEFT, IJ30420 PERSSISTS AFTER

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • 7612 -
    
    When a Radio Button Group control is dragged to the application
    
    canvas in Application Designer, the Text Alignment is
    LEFT, then the header is justified to the left.
    However, when you extend the screen in the application, using
    the mouse
    cursor in the right corner of the screen and holding and
    dragging to the right,
    until it fills the entire area of the screen on your monitor,
    the text alignment
    of the Radio Button group loses its formatting. and is shifted
    to the right,
    in the same proportion as the screen was expanded.
    
    
    
    STEPS TO REPLICATE:
    1-Open Maximo as maxadmin
    2-Go to Application Designer application
    3-Open an application canvas like PR application
    4-Open the Control Pallette and drag a Radio Button Group
    control
    You will see that the Radio Group Control header will remain to
    the left.
    
    5-Open Maximo application, in case PR.
    6-Extend the PR screen in the application, using the mouse
    cursor in the right corner of the screen and holding and
    dragging to the right.
    
    CURRENT ERRONEOUS RESULT:
    The text alignment of the Radio Button group loses its
    formatting. and is shifted to the right,
    in the same proportion as the screen was expanded.
    
    EXPECTED RESULT:
    The header is justified to the left.
    
    System Information:
    App Server IBM WebSphere Application Server 9.0.5.11
    Version
    Tivoli's process automation engine 7.6.1.2-IFIX20220216-1819
    Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-76
    IBM Maximo Asset Management Work Centers 7.6.0.4 Build
    20200715-0100 DB Build V7604-119 HFDB Build HF7680-10
    IBM Maximo Enterprise Adapter for Oracle Applications 7.6.1.0
    Build 20200901-1037 DB Build V7610-02
    IBM Tpae Integration Framework
    7.6.1.2-MIF_7612_IFIX.20211006-1305 Build 20200715-1444 DB Build
    V7612-11 HFDB Build HF7612-02
    IBM Maximo Asset Management 7.6.1.2 Build 20200715-0100 DB Build
    V7611-01
    IoT Connection Utility 7.6.0.3 Build 20200701-1409 DB Build
    V7603-32
    IBM Maximo Health, Safety and Environment Manager
    7.6.1.0-20220107-1513 Build 20161020-0816 DB Build V7610-01
    Server OS Windows Server 2019 10.0
    Server DB Microsoft SQL Server 15.0 (15.00.4198)
    (c) Copyright IBM Corp. 2020
    

Local fix

  • To hide the label in Radio Group Properties, Then Include a
    Static Text into Radio Button Session.
    Open the Static text properties, set the desired label, and set
    Text Alignment to the Left.
    Save the application definition.
    

Problem summary

  • ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * RADIO BUTTON GROUP CONTROL TEXT ALIGNMENT IS LEFT BUT THE    *
    * HEADER IS NOT JUSTIFIED TO THE LEFT                          *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR will be included in a future release
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ44238

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-11-10

  • Closed date

    2023-09-13

  • Last modified date

    2023-09-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date: