PH49445: BACKUP OPTION FOR INPUT CARDS DOES NOT CREATE FILES USING A RELATIVE PATH WHEN RUN UNDER REST API

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • It may be observed that when using the IBM Transformation
    Extender (ITX) 10.1.x REST API to execute maps, backup file
    locations that are specified with a relative path will NOT
    create the backup files in the expected place.
    
    Example:  A map placed under /data/maps with a backup location
    set to ../backup/
    
    The same map run under Command Server would create the backup
    files in /data/backup/.  The REST API potentially would fail to
    create the backup files, or they may appear in an unexpected
    location.
    

Local fix

  • ITXCQ - ITX00061512
    PB / PB
    Circumvention: None
    

Problem summary

  • Users Affected:
    IBM Transformation Extender users using REST API and backup
    files in input or output card with relative path.
    
    Problem Description:
    Backup option for input cards does not create files using a
    relative path when run under REST API.
    
    Platforms Affected:
    All
    

Problem conclusion

  • Prevent error by determining the correct absolute path.
    
    Applies to:
    10.1.1.1
    
    Fixed in the next service packs and releases.
    
    To obtain the fix for this APAR:
    
    To see if the next service pack or product release is available,
    check the IBM Transformation Extender Release Notes page:
    https://www.ibm.com/support/docview.wss?uid=swg27008337
    
    If the service pack or product release is available, download it
    from Fix Central:
    http://www.ibm.com/support/fixcentral/
    
    If the service pack or product release is not available and you
    require the APAR fix immediately, request a Limited Availability
    Interim Fix (LAIF) by opening a case:
    https://www.ibm.com/mysupport/
    
    Prior to version 9.0.0, IBM Transformation Extender was called
    IBM WebSphere Transformation Extender.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH49445

  • Reported component name

    ITX

  • Reported component ID

    5724Q2300

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-09-13

  • Closed date

    2022-11-15

  • Last modified date

    2022-11-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ITX

  • Fixed component ID

    5724Q2300

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVSD8","label":"Transformation Extender"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10"}]

Document Information

Modified date:
19 November 2022