A fix is available
APAR status
Closed as program error.
Error description
In a COBOL program that attempts to open an empty VSAM file as EXTEND, has an Error Declarative which then opens the file as OUTPUT, and also contains an OCCURS DEPENDING ON clause, incorrect output may be received when the program is compiled with OPT(0).
Local fix
Compile with OPT(1) or OPT(2); Open the file as OUTPUT (not EXTEND)
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL compiling * * programs that contain GO TO statements that * * branch from a DECLARATIVE section to normal * * PROCEDURE DIVISION code. * **************************************************************** * PROBLEM DESCRIPTION: Program may produce unexpected results * * or have unexpected behaviour if the * * program exits a DECLARATIVE section * * via a GO TO * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** The compiler generated code to access data items in the PROCEDURE DIVISION on the program's main stack. DECLARATIVE sections have their own stack. DECLARATIVE section code that returns to the PROCEDURE DIVISION with a GO TO circumvented the normal transfer of control from the DECLARATIVE section to the PROCEDURE DIVISION, causing the code to use the DECLARATIVE section's stack isntead of the PROCEDURE DIVISON stack.
Problem conclusion
The compiler was fixed to find the program's stack before referring to data items in the program, regardless of which stack frame was current.
Temporary fix
Comments
APAR Information
APAR number
PH50236
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-10-17
Closed date
2022-11-23
Last modified date
2023-01-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI83433
UP22/12/01 P F211
R631 PSY UI83434
UP22/12/01 P F211
R632 PSY UI83435
UP22/12/01 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023