A fix is available
APAR status
Closed as program error.
Error description
When the zDLA discovery job is run on z/OS, IZDSSUBI gets a 0E0 abend when a subsystem is in the process of coming up.
Local fix
Re-run the zDLA discover job.
Problem summary
**************************************************************** * USERS AFFECTED: Users of zOS DLA V310 * **************************************************************** * PROBLEM DESCRIPTION: ABEND0E0 can occur due to a subsystem * * in the process of coming up when z/OS * * DLA discovery job is being run. * * * * Additional search keyword: ABEND0E0 * **************************************************************** An ABEND0E0 can occur while IZDSSUBI discovers information from running address spaces when these address spaces are not ready or terminates during that time of discovery. Because the ABEND is not recovered, zOS DLA discovering terminates earlier than expected, and abend 0E0 is percolated.
Problem conclusion
z/OS DLA will recover from ABEND0E0 and will continue to discover information that is available.
Temporary fix
Comments
APAR Information
APAR number
OA63544
Reported component name
Z/OS DLA
Reported component ID
5698A4700
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-07-28
Closed date
2022-11-21
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ09547
Modules/Macros
IZDRDLA IZDSSUBI
Fix information
Fixed component name
Z/OS DLA
Fixed component ID
5698A4700
Applicable component levels
R310 PSY UJ09547
UP22/11/29 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310"}]
Document Information
Modified date:
01 December 2022