IBM Support

PH48673: The >>DATA directive should only be used in WORKING-STORAGE, but is silently ignored in LINKAGE & LOCAL-STORAGE sections

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When the >>DATA directive for LP(64) programs is specified in
    the LINKAGE or LOCAL-STORAGE sections of the DATA DIVISION, the
    directive is ignored and no error message is produced.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.4                *
    *                 compiling programs that specify the          *
    *                 DATA directive in a part of the              *
    *                 DATA DIVISION that is not the                *
    *                 WORKING-STORAGE section.                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Missing compiler error message.         *
    *                                                              *
    *                      The DATA directive is only supported    *
    *                      in the WORKING-STORAGE SECTION of the   *
    *                      DATA DIVISION. When the DATA            *
    *                      directive is specified in an            *
    *                      unsupported section of the DATA         *
    *                      DIVISION, the directive was             *
    *                      ignored and no error message was        *
    *                      produced.                               *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM supplied PTF                   *
    ****************************************************************
    The compiler code that was parsing the DATA directive was not
    properly checking that a DATA directive was only specified in
    the WORKING-STORAGE SECTION of the DATA DIVISION. If it was
    specified in the LINKAGE SECTION or the LOCAL-STORAGE SECTION of
    the DATA DIVISION, the directive was ignored without emitting
    any error indication to the compiler user.
    

Problem conclusion

  • The compiler has been updated so that it properly checks that a
    DATA directive only appears in the WORKING-STORAGE SECTION of
    the DATA DIVISION. If a DATA directive is found anywhere else
    in the users' source program, an error message is produced and
    the directive is ignored.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH48673

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-08-12

  • Closed date

    2022-08-18

  • Last modified date

    2022-11-01

  • APAR is sysrouted FROM one or more of the following:

    PH47504

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYADXIT IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV
    IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3
    IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE
    IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5
    IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJBLD IGYCJBLS IGYCJDM1 IGYCJDM2
    IGYCJDM3 IGYCJDM4 IGYCJDM5 IGYCJDM6 IGYCJDMB IGYCJDMR IGYCJGEN
    IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8
    IGYCMALL IGYCOPI  IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC
    IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2
    IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF
    IGYDRV   IGYEQCWI IGYISMKD IGYMSGE  IGYMSGK  IGYMSGT  IGYMSGXT
    IGYQC    IGYQCB   IGYQCBE  IGYQCBG  IGYQSPLT IGYWACPT IGYWALOC
    IGYWAPLY IGYWC    IGYWCL   IGYWCLG  IGYWDDEF IGYWDOPT IGYWIVP1
    IGYWIVP2 IGYWRECV IGYWRWD  IGYWSMPE IGYWUOPT IGYWZFS  IGYZQEN6
    IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R640 PSY UP

       A

  • R641 PSY UP

       A

  • R642 PSY UI82932

       UP22/10/28 P F210

  • R64H PSY UP

       A

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: