IBM Support

PH48666: WHEN THE ARGUMENT TO THE SIGN INTRINSIC FUNCTION IS A NUMERIC LITERAL, THE COMPILER ABENDS WITH ERROR IGYPG5201-U

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When the argument to the SIGN intrinsic function is a numeric
    literal, the compiler abends with error:
    
    CURRENT PHASE: IGYCPGEN
    CURRENT LINE NUMBER: 000017
    REGISTERS 0 - 15:
    2B399456 00000000 0008A948 00000000         0001EDD0 00000000
    00000000 0008A8F5
    00000000 00000000 00017A14 2B387B48         2B399324 2B399068
    AB387716 00011DC2
    
    LineID  Message code  Message text
    000017  IGYPG5125-U   The compilation was terminated due to a
    compiler error in phase id:  "IGYCPGEN".
    
    000017  IGYPG5201-U   Internal compiler error code "PTEXT-07"
    occurred.
    

Local fix

  • Moving the numeric literal argument into an appropriate data
    item and using the data item as the argument to the SIGN
    intrinsic function will prevent the error and result in a clean
    compile.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling      *
    *                 programs that contain an invocation of the   *
    *                 SIGN intrinsic function with a numeric       *
    *                 literal argument.                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler abort with the following       *
    *                      message:                                *
    *                                                              *
    *                      IGYPG5125-U   The compilation was       *
    *                      terminated due to a compiler            *
    *                      error in phase id:  "IGYCPGEN".         *
    *                                                              *
    *                      IGYPG5201-U   Internal compiler error   *
    *                      code "PTEXT-07" occurred.               *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM-provided PTF.                  *
    ****************************************************************
    An optimization in the compiler for handling literal
    arguments to the SIGN intrinsic function could result
    in a compiler abort.
    

Problem conclusion

  • The compiler was updated to ensure that literal arguments for
    the SIGN intrinsic function are handled correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH48666

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    640

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-08-12

  • Closed date

    2022-08-18

  • Last modified date

    2022-11-01

  • APAR is sysrouted FROM one or more of the following:

    PH47472

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYADXIT IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV
    IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3
    IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE
    IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5
    IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJBLD IGYCJBLS IGYCJDM1 IGYCJDM2
    IGYCJDM3 IGYCJDM4 IGYCJDM5 IGYCJDM6 IGYCJDMB IGYCJDMR IGYCJGEN
    IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8
    IGYCMALL IGYCOPI  IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC
    IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2
    IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF
    IGYDRV   IGYEQCWI IGYISMKD IGYMSGE  IGYMSGK  IGYMSGT  IGYMSGXT
    IGYQC    IGYQCB   IGYQCBE  IGYQCBG  IGYQSPLT IGYWACPT IGYWALOC
    IGYWAPLY IGYWC    IGYWCL   IGYWCLG  IGYWDDEF IGYWDOPT IGYWIVP1
    IGYWIVP2 IGYWRECV IGYWRWD  IGYWSMPE IGYWUOPT IGYWZFS  IGYZQEN6
    IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R640 PSY UP

       A

  • R641 PSY UP

       A

  • R642 PSY UI82932

       UP22/10/28 P F210

  • R64H PSY UP

       A

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023