APAR status
Closed as program error.
Error description
In cases when the EC's internal process table is full but a new entry is demanded due to the request to start a new process a FFST with probeid XC037007 is thrown, and the causing processes internal trace indentation gets misaligned.
Local fix
Problem summary
In case of the error situation for XC037007 the code made an early jump to its exit where the trace indentation is decreased, however the trace indentation was not increased before that.
Problem conclusion
Code has been changed to increase trace indentation before executing this specific block --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v8.1 8.1.0.11 The latest available maintenance can be obtained from 'Recommended Fixes for IBM MQ' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037 If the maintenance level is not yet available information on its planned availability can be found in 'IBM MQ planned maintenance release dates' http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT41774
Reported component name
MQ FOR HPE NS O
Reported component ID
5724A3904
Reported release
810
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-08-15
Closed date
2022-08-15
Last modified date
2022-08-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MQ FOR HPE NS O
Fixed component ID
5724A3904
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"810","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
15 August 2022