Error description

  • When a called assembler program returns to the COBOL caller, an
    incorrect code path may be taken when the calling routine checks
    the Return-Code Special Register.  When the COBOL program is
    compiled with OPT(2), an incorrect length may used in the
    comparison for Return-Code Special Register.
    

Local fix

  • BYPASS/CIRCUMVENTION:
    Compile the calling program with OPT(0).  Called assembler
    program should also ensure a valid value in reg15 upon return to
    the calling COBOL program.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling and  *
    *                 running programs with the OPT(1|2) option in *
    *                 effect and the program contains a CALL       *
    *                 statement and one of the following is true:  *
    *                                                              *
    *                 1) the program contains a reference to the   *
    *                 RETURN-CODE special register after the CALL  *
    *                 statement; OR                                *
    *                                                              *
    *                 2) the CALL statement contains a RETURNING   *
    *                 phrase and the returned value receiver data  *
    *                 item is a 2-byte binary numeric item (i.e.,  *
    *                 usage COMP/COMP-4/COMP-5/BINARY) and the     *
    *                 program contains a reference to that         *
    *                 returned value after the CALL statement      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrect run time result.              *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM-provided PTF.                  *
    ****************************************************************
    The COBOL compiler optimizer could, under certain circumstances,
    mishandle the RETURN-CODE special register or a 2-byte binary
    numeric returned value leading to an incorrect result.
    

Problem conclusion

  • The COBOL compiler was updated to ensure that program
    optimization does not lead to incorrect handling of the
    RETURN-CODE special register and 2-byte binary numeric returned
    values.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH44764

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-09

  • Closed date

    2022-07-22

  • Last modified date

    2022-08-02

  • APAR is sysrouted FROM one or more of the following:

    PH44015

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI  IGYCOSCN IGYCPGEN IGYCRCTL
    IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0
    IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D
    IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT
    IGYQCB   IGYQCBE  IGYQCBG  IGYQSPLT IGYTCARA IGYTSALE IGYZQEN6
    IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI81630

       UP22/07/29 P F207

  • R631 PSY UI81631

       UP22/07/29 P F207

  • R632 PSY UI81632

       UP22/07/29 P F207

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023