Preventive Service Planning
Abstract
These recommendations are based upon your system already having installed the most current Cumulative PTF Package, HIPER PTF Group, and Database PTF Group.
Content
Recommendations
The i Global Support Center recommends installing the PTFs listed below for corrective service and preventive maintenance. If a problem persists after the recommended fixes have been installed, the support engineers can more efficiently diagnose the issue.
For further information or to order these PTFs, follow this link: http://www.ibm.com/support/fixcentral/
The Rochester Support Center recommends installing the group and individual fixes listed below for corrective service and preventive maintenance. If a problem persists after the recommended fixes have been installed, the Rochester Support Center can more efficiently diagnose the problem and additional fixes may be recommended.
V7R5M0 | <-- Click here to execute the Fix Central Quick Order feature to order all of the PTFs on this list |
Important Note: By clicking the link above, an order for all appropriate release PTFs on the list below will be placed through Fix Central. You will not need to type the individual PTF numbers. You will have the opportunity to deselect any PTFs you do not want in the order before continuing with the order process. |
This document also includes QNTC and SAMBA PTFs as well since they are related to SMB support.
Note: Click on the PTF number to review the PTF cover letter. The PTF cover letter contains a description of what the PTF resolves, information about the PTF(s) it supersedes, if any, and any special instructions that need to be performed to apply the PTF. |
Date Added to List (MM/DD/YYYY) | Fix / Release (Link to PTF Cover Letter) |
Licensed Program
Product
|
Cumulative
Package
|
Description |
11/18/2022 | SI81748 | 5770SS1 | None | OSP-INCORROUT-MSGCPFA0D4 QNTC directory failure with error n |
12/09/2022 | SI81908 | 5770SS1 | None | OSP-OTHER QNTC FAILS WITH EXTRANEOUS MESSAGES |
02/08/2023 | SI82375 | 5770SS1 | None | OSP-INCORROUT QNTC FAILS WITHOUT ANY ERROR MESSAGE |
02/16/2023 | SI82627 | 5770SS1 | None | OSP-OTHER MULTIPLE QNTC PROBLEMS |
03/14/2023 | SI82935 | 5770SS1 | None | OSP-OTHER-WAIT JOB USING QNTC FILE SYSTEM HANGS |
Note: The CHGUSRPRF command can no longer be used to reset, or re-enable, a user that is disabled for NetServer access as it was in the past on earlier OS versions (710 and below). You should refer to APAR MA42015 for additional information. Individual users can be re-enabled by using the GO NETS menu, using IBM i Navigator, or by writing a program that makes use of the QZLSCHSI API. All profiles are re-enabled for IBM i NetServer use, when IBM i NetServer is restarted from the IBM i Navigator or by running the STRTCPSVR *NETSVR command. All profiles are also re-enabled for IBM i NetServer use when the system is IPLed.
IBM Document 684479 - CL Program and Command to Re-Enable NetServer Users contains a sample as-is CL program that uses the QZLSCHSI API to re-enable NetServer users and a sample command that can be used to run the program.
IBM Document 683941 - Automatically Re-Enable a Disabled IBM i NetServer User Profile contains a sample as-is CL program that uses the QZLSCHSI API to re-enable NetServer users and a sample WATCH program that can be used to run the re-enablement program automatically whenever a CPIB682 "User Profile disabled" message is received on the IBM i.
IBM Document 684479 - CL Program and Command to Re-Enable NetServer Users contains a sample as-is CL program that uses the QZLSCHSI API to re-enable NetServer users and a sample command that can be used to run the program.
IBM Document 683941 - Automatically Re-Enable a Disabled IBM i NetServer User Profile contains a sample as-is CL program that uses the QZLSCHSI API to re-enable NetServer users and a sample WATCH program that can be used to run the re-enablement program automatically whenever a CPIB682 "User Profile disabled" message is received on the IBM i.
Important Information
For more information on Cumulative PTF packaging, go to the following URL: Roadmap to IBM i Preventive Service Planning Documentation
Installation / Upgrade Considerations
For special instructions, review the cover letter for each PTF. You can review the specific cover letter by clicking on the PTF number in the above table, or search for PTF cover letters using the following link: PTF Cover Letter Search
For more information on ordering PTFs through Fix Central, refer to IBM Document 643763
For more information on Cumulative PTF packaging, go to the following URL: Roadmap to IBM i Preventive Service Planning Documentation
Installation / Upgrade Considerations
For special instructions, review the cover letter for each PTF. You can review the specific cover letter by clicking on the PTF number in the above table, or search for PTF cover letters using the following link: PTF Cover Letter Search
For more information on ordering PTFs through Fix Central, refer to IBM Document 643763
[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSB23CE","label":"IBM i 7.5 Preventative Service Planning"},"ARM Category":[{"code":"a8m0z0000000C4BAAU","label":"IBM i"}],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.5.0"}]