Error description

  • On tenants, the throttler will not be trigger upon exceeding the
    configured memory threshold. Tenant memory appears to not be pr
    operly tracked, so the throttler may not trigger at the set limi
    t.
    

Local fix

Problem summary

  • On tenants, the throttler might not be triggered upon exceeding
    the configured memory threshold.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT40957

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    A0X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-03

  • Closed date

    2022-06-16

  • Last modified date

    2022-06-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A0X"}]

Document Information

Modified date:
17 June 2022