IBM Support

Login prompt does not appear when connecting to TM1 server in Architect/Perspectives.

Troubleshooting


Problem

TM1 Architect/Perspectives displays the TM1 Server(s) from a client machine. After clicking on the server name to connect nothing happens. 

Symptom

The login screen does not appear in TM1 Architect/Perspectives when connecting to a TM1 Server. 

Cause

One of the reasons behind login prompt not showing up could be that the client version i.e. Architect/Perspectives version is higher (more recent) than the TM1 server version.
TM1 client version should always be equal or lower than the TM1 server version.

Diagnosing The Problem

Check the Architect version and the TM1 server version

Resolving The Problem

Ensure to have the same or lower Architect/Perspectives version corresponding to the TM1 server version.
For example, if the TM1 server version is 2.0.9.14 then the client version should be 2.0.9.14 or lower.

Document Location

Worldwide

[{"Type":"MASTER","Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCTEW","label":"IBM Planning Analytics Local"},"ARM Category":[{"code":"a8m3p000000PC6lAAG","label":"Planning Analytics-\u003EArchitect"}],"ARM Case Number":"","Platform":[{"code":"PF033","label":"Windows"}],"Version":"All Versions"}]