IBM Support

JR64849: THE EXPOSED PROCESS DISAPPEARS FROM THE PROCESS PORTAL AFTER RUNNING AN UNNAMED SNAPSHOT CLEANUP SERVICE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • When you run an unnamed snapshot cleanup service with
    -keptNumber 0, it deletes all unnamed snapshots. As a result,
    some exposed processes get removed from the Process portal.
    

Local fix

  • -Set the -keptNumber value to more than 0.
    

Problem summary

  • This issue happens because the records in the lsw_favorite table
     reference the old version of the tip snapshot.
    
    PRODUCT AFFECTED:
    IBM Business Automation Workflow
    IBM Cloud Pak for Business Automation
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    JR64849

  • Reported component name

    BUS AUTO WORKFL

  • Reported component ID

    5737H4100

  • Reported release

    K00

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-04-14

  • Closed date

    2022-04-25

  • Last modified date

    2022-04-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"20.0.0.1"}]