PH45738: RANDOM FUNCTION DISPLAYS A MISLEADING RT MESSAGE WHEN INPUT IS GREATER THAN 2147483645 FOR AMODE64

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Random function displays a misleading RT message when input is
    greater than 2147483645 for AMODE64
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.3 and later      *
    *                 releases running programs in AMODE 64        *
    *                 compiled with TRUNC(BIN) using the RANDOM    *
    *                 intrinsic function.                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: COBOL programs running in AMODE 64      *
    *                      compiled with TRUNC(BIN) using the      *
    *                      RANDOM intrinsic function terminate     *
    *                      with run-time error message IGZ0163S    *
    *                      during execution when value +2147483647 *
    *                       is passed as an input argument to the  *
    *                       RANDOM intrinsic function.             *
    ****************************************************************
    * RECOMMENDATION: Install provided PTF.                        *
    ****************************************************************
    There was a logic error in the runtime routine for intrinsic
    function RANDOM when value +2147483647 was passed an input
    argument in programs running in AMODE 64 compiled with
    TRUNC(BIN), causing terminating run-time error message IGZ0163S
    during program execution.
    
    COB0603T/K
    

Problem conclusion

  • The logic in the runtime routine for intrinsic function RANDOM
    has been corrected to accept the value +2147483647 as an input
     in AMODE 64 programs compiled with TRUNC(BIN).
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH45738

  • Reported component name

    LE ENT COBOL LI

  • Reported component ID

    568819812

  • Reported release

    7D0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-04-18

  • Closed date

    2022-04-27

  • Last modified date

    2022-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI80299 UI80301 UI80302

Modules/Macros

  • CELQSG04 CELQV004 IGZQAPI  IGZQCA64 IGZQCDA  IGZQINPL IGZQIUXB
    IGZQJNI2 IGZQR004
    

Fix information

  • Fixed component name

    LE ENT COBOL LI

  • Fixed component ID

    568819812

Applicable component levels

  • R7B0 PSY UI80299

       UP22/04/29 P F204

  • R7C0 PSY UI80301

       UP22/04/29 P F204

  • R7D0 PSY UI80302

       UP22/05/02 P F204

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7D0"}]

Document Information

Modified date:
04 May 2022