Troubleshooting
Problem
If you installed starter pattern with BAStudio before 21.0.3-IF007 (21.0.3). Then after you upgraded the operator to 21.0.3-IF007. You may meet an error
MountVolume.SetUp failed for volume "encrypt-store" : references non-existent secret key: jvm.options
Resolving The Problem
You can solve this issue by editing bastudio admin secret by the following steps below:
1. oc edit <cr-name>-bas-admin-secret
2. Remove the key: oidcClientSecret
3. Save the edit and wait for the operator to reconcile.
Document Location
Worldwide
[{"Type":"MASTER","Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSBYVB","label":"IBM Cloud Pak for Business Automation"},"ARM Category":[{"code":"a8m0z0000001iTbAAI","label":"Operate-\u003EBAS App Management"}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"21.0.3"}]