IBM Support

IBM Spectrum Scale : Spectrum Scale may exhibit a restart of the Spectrum Scale daemon or a failure to mount a filesystem when configured with RDMA

Troubleshooting


Problem

On RDMA enabled Spectrum Scale clusters with Infiniband or RoCE interconnects, this cluster might show
  • an intermittent restart of the Spectrum Scale daemon
  • a client node failing to mount a filesystem.
The Spectrum Scale logs show entries like 
logAssertFailed: wcOpcode == IBV_WC_SEND || wcOpcode == IBV_WC_RDMA_READ || wcOpcode == IBV_WC_RDMA_WRITE

Cause

The MOFED layer 5.4-2.X can return incompatible/unsupported responses to I/O requests issued by Spectrum Scale. As a part of recovery, the Spectrum Scale daemon might terminate and restart. This issue was introduced in MOFED version 5.4-2.0. Earlier versions of MOFED are not impacted.

Environment

All Spectrum Scale releases are impacted.

Resolving The Problem

While a permanent fix is being worked on, downgrading MOFED to version 5.4-1.X is an interim circumvention of the issue. See below for steps on how to downgrade to MOFED version to 5.4-1.0.3.0.
Downgrading MOFED to version to 5.4-1.0.3.0:
Note: Firmware levels will not change in this process and will remain the same as with 5.4-2
Prerequisites:
  1.  Check MOFED level on each cluster node to see whether the cluster is affected ofed_info -s
  2. Make sure you have the right Drivers for the installation
-rw-r--r-- 1 root root 366528512 Jul 16 11:57 MLNX_OFED_LINUX-5.4-1.0.3.0-rhel8.2-ppc64le.iso
-rw-r--r-- 1 root root 410331136 Jul 16 11:58 MLNX_OFED_LINUX-5.4-1.0.3.0-rhel8.2-x86_64.iso
Steps for downgrading :
Note: These are high-level instructions on how to downgrade from MOFED 5.4-2 to MOFED 5.4-1. This instruction set assumes the cluster stays online. The examples below are based on the ppc64le architecture. Make the changes where appropriate.
  1. Log in to the first node requiring MOFED downgrade
    •  ssh node1
  2. Check the MOFED version (downgrade required if > 5.4-1.0.3.0)
    • ofed_info -s
  3. Verify quorum availability (if cluster must remain online).
    • mmgetstate -s Verifies quorum and help determine whether taking down one or more nodes is safe to keeping the cluster up.
  4. Shutdown Spectrum Scale (on this node)
    • mmshutdown
  5. Verify Spectrum Scale is shutdown (on this node)
    • mmgetstate
  6. Uninstall the existing MOFED version
    •  /sbin/ofed_uninstall.sh --force
  7. Copy MOFED iso and firmware binary the node (example by using ppc64le and sftp)
    • sftp node1
    • cd /tmp
    • mput MLNX_OFED_LINUX-5.4-1.0.3.0-rhel8.2-ppc64le.iso
  8.  Mount MOFED iso
    • cd /tmp ; mount -o loop MLNX_OFED_LINUX-5.4-1.0.3.0-rhel8.2-ppc64le.iso /mnt
  9. Install MOFED (with sample options)
    • cd /mnt ; ./mlnxofedinstall --add-kernel-support --disable-kmp --without-fw-update
  10.  Remove MOFED udev rules (if applicable)
    • Mellanox OFED v5.x applies custom networking udev rules that might interfere with user-defined versions.
    • How to determine whether a modification is needed?
      • cat /proc/cmdline
    • If you see the following lines => [biosdevname=0 net.ifnames=0] do the following:
      • mv -f /lib/udev/rules.d/82-net-setup-link.rules /lib/udev/rules.d/82-net-setup-link.rules.bak
  11. Re-create initramfs (example for RHEL using dracut)
    • dracut -f
  12. Reboot the node
    • systemctl reboot
  13. Confirm MOFED driver is running
    • lbstat
    • ofed_info -s
    • ibdev2netdev
  14. Start Spectrum Scale
    • mmstartup
  15. Confirm Spectrum Scale is active and quorum met
    • mmgetstate -a
    • mmgetstate -s

Document Location

Worldwide

[{"Type":"MASTER","Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"STXKQY","label":"IBM Spectrum Scale"},"ARM Category":[{"code":"a8m3p000000PC7yAAG","label":"non-GPFS"}],"ARM Case Number":"","Platform":[{"code":"PF016","label":"Linux"}],"Version":"All Versions"}]

Document Information

Modified date:
16 February 2022

UID