Error description
After upgrading ILMT from 9.2.25 to 9.2.26, we are unable to login to the ILMT website with IE due to the following message. Internet explorer error: There is a problem with this website?s security certificate. The security certificate presented by this website is not secure. Security certificate problems may indicate an attempt to fool you or intercept any data you send to the server. We recommend that you close this webpage and do not continue to this website TS007866886
Local fix
login with FireFox or Chrome open up 'Management: Server Settings' and Generate a new self-signed certificate. Restart ILMT to pick up the certificate replacement
Problem summary
**************************************************************** ***************** ERROR DESCRIPTION: After upgrading ILMT from 9.2.25 to 9.2.26, we are unable to login to the ILMT website with IE due to the following message. Internet explorer error: There is a problem with this website?s security certificate. The security certificate presented by this website is not secure. Security certificate problems may indicate an attempt to fool you or intercept any data you send to the server. We recommend that you close this webpage and do not continue to this website TS007866886 **************************************************************** ***************** * EXPECTED RESULTS: * The issue does not occur. **************************************************************** * RECOMMENDATION: Apply appropriate update when available. ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following maintenance packages: | Update | ILMT 9.2.27.0 ****************************************************************
Temporary fix
Comments
APAR Information
APAR number
IJ36903
Reported component name
LIC METRIC TOOL
Reported component ID
5724LMTEM
Reported release
920
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-12-29
Closed date
2022-01-04
Last modified date
2022-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
LIC METRIC TOOL
Fixed component ID
5724LMTEM
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS8JFY","label":"IBM License Metric Tool"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"920"}]
Document Information
Modified date: