IBM Support

PH42022: WITH ZONEDATA=MIG SET IN IGYCDOPT, ZONEDATA(NOPFD) INCORRECTLY MAPS TO INVDATA(FNC,CS) INSTEAD OF INVDATA(NOFNC,CS)

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When ZONEDATA=MIG set as a default in the IGYCDOPT compiler
    options default module, then if a compile is done using
    ZONEDATA(NOPFD), the compiler incorrectly maps ZONEDATA(NOPFD)
    to INVDATA(FORCENUMCMP,CLEANSIGN) instead of
    INVDATA(NOFORCENUMCMP,CLEANSIGN).
    The problem only occurs when both of these are true:
    1) The default set in IGYCDOPT module is ZONEDATA=MIG.
    2) A compile is done with ZONEDATA(NOPFD) to override the
    default.
    

Local fix

  • Replace ZONEDATA(NOPFD) in the compile JCL with the INVDATA
    compiler option (with no suboptions).
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and  *
    *                 running programs where the ZONEDATA=MIG      *
    *                 compiler option is specified in the          *
    *                 installation defaults for the compiler but   *
    *                 is overridden with either the                *
    *                 ZONEDATA(NOPFD)                              *
    *                 or ZONEDATA(PFD) option during compiler      *
    *                 invocation.                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Unexpected runtime behavior for         *
    *                      comparisons involving zoned and/or      *
    *                      packed data items containing invalid    *
    *                      data. The comparison is done as if the  *
    *                      deprecated ZONEDATA(MIG) option, or its *
    *                      equivalent INVDATA(FORCENUMCMP,...),    *
    *                      were in effect.                         *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM-provided PTF.                  *
    ****************************************************************
    When mapping the deprecated ZONEDATA(PFD) and ZONEDATA(NOPFD)
    options to INVDATA during options processing, some bits that
    were set during installation defaults processing for ZONEDATA
    were not properly cleared.
    

Problem conclusion

  • The compiler was updated so that when the mapping from
    ZONEDATA(PFD) and ZONEDATA(NOPFD) to the new INVDATA option is
    done, bits from the ZONEDATA installation defaults are properly
    cleared, if set.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH42022

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-11-10

  • Closed date

    2021-11-18

  • Last modified date

    2021-12-01

  • APAR is sysrouted FROM one or more of the following:

    PH41801

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR
    IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1
    IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R
    IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE
    IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R630 PSY UI78163

       UP21/11/25 P F111

  • R631 PSY UI78164

       UP21/11/25 P F111

  • R632 PSY UI78165

       UP21/11/25 P F111

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
12 December 2023