Critical issue for production upgrades from IBM® Engineering Requirements DOORS Next 6.x to 7.0.2 iFix008: Some data not visible after upgrade (Updated)

News


Abstract

We identified a defect, which impacted upgrades from IBM® Engineering Requirements DOORS Next 6.x to 7.0.2 iFix008 only.
We have since resolved the problem and reissued iFix008 as iFix008a

Content

In edge cases where data in IBM® Engineering Requirements DOORS Next 6.x has certain characteristics, the upgrade left an unusable version of that data in 7.0.2 iFix008. 
We have now resolved the issue and reissued the iFix008 as iFix008a. 
Any customers that downloaded iFix008 and have not upgraded should not upgrade from IBM® Engineering Requirements DOORS Next 6.0.6.x to 7.0.2 using 7.0.2 iFix008.  Instead, download iFix008a.
If necessary, in test scenarios customers can continue testing 7.0.2 iFix008 upgrades, performance, and functionality. 
 
How to detect if this issue impacted your upgrade:
In the logs directory of IBM® Engineering Requirements DOORS Next, find the repotools-rm.log (example: JAZZ_HOME/liberty/servers/clm/logs)
Linux:
grep -c "that had an invalid current version" repotools_rm.log
Providing that the logger configuration was including INFO
On Windows use PowerShell:
Get the string values we are looking for:
Select-String repotools-rm.log -Pattern “that had an invalid current version" > C:\Temp\invalid.txt
Count the number of items found:
(Get-Content C:\Temp\invalid.txt).Length
What to do if this issue is detected in your logs?
  •  If the number of lines returned by the commands is greater than 0.
  •  The number returned does not indicate the actual number of affected artifacts.
Contact IBM Support if the issue is detected and your IBM® Engineering Requirements DOORS Next 7.0.2 iFix008 system is in production.
 

[{"Type":"MASTER","Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSUVLZ","label":"IBM Engineering Requirements Management DOORS Next"},"ARM Category":[{"code":"a8m50000000Cj3xAAC","label":"DOORS Next->Upgrade->DNG Specific"}],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.2"}]