Error description
If you have an application of the following form, running on IBM Integration Bus, it may fail after migrating to ACE V11. ++++++++ Shared library containing 2 subflows. One inner subflow that has a UDP property and the inner subflow is added to an outer subflow . The outer subflow has promoted the UDP (of the subflow node) to flow level. The outer subflow is then added to the main application and the value of UDP is set in the main application flow. ++++++
Local fix
Redeploy the subflows.
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM App Connect Enterprise V12 and V11, migrated from IBM Integration Bus, having user-defined property on subflow node. Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: <span style="background-color:rgb(255, 255, 255)">If you have an application of the following form, running on IBM </span><span style="background-color:rgb(255, 255, 255)">Integration Bus, it may fail after migrating to App Connect Enterprise. </span> <span style="background-color:rgb(255, 255, 255)"> </span> <span style="background-color:rgb(255, 255, 255)">_____________ </span> <span style="background-color:rgb(255, 255, 255)">Shared library containing 2 subflows. One inner subflow that has </span><span style="background-color:rgb(255, 255, 255)">a UDP property and the inner subflow is added to an outer </span><span style="background-color:rgb(255, 255, 255)">subflow . The outer subflow has promoted the UDP (of the </span><span style="background-color:rgb(255, 255, 255)">subflow node) to flow level. The outer subflow is then added to </span><span style="background-color:rgb(255, 255, 255)">the main application and the value of UDP is set in the main </span><span style="background-color:rgb(255, 255, 255)">application flow. </span> <span style="background-color:rgb(255, 255, 255)">____________ An application of the above form, when migrated to App Connect Enterprise V11 or V12, will fail to override the UDP with the value set in main application flow. </span>
Problem conclusion
The product is fixed to correctly override UDP of subflows with the value set in the parent flow. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v11.0 11.0.0.15 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT38505
Reported component name
APP CONNECT ENT
Reported component ID
5724J0550
Reported release
B00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-09-27
Closed date
2021-10-29
Last modified date
2021-10-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
APP CONNECT ENT
Fixed component ID
5724J0550
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]
Document Information
Modified date:
30 October 2021