IBM Support

PH41479: UPDATE THE MESSAGE IN THE IGYCDOPT DEFAULT COMPILER OPTION BUILD PROCESS TO BETTER EXPLAIN INCORRECT VALUES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • APAR PH36777 added code to SIGYMAC(IGYCOPT) to recognize the
    problem when administrators incorrectly coded OPTION( ) instead
    of OPTION=( ) or coded an unknown compiler option.
    Administrators are getting confused because the *** MNOTE ***
    message says OPT=VALUE instead of OPTION=VALUE.  They
    mistakenly think that there is a problem with the OPT
    (OPTIMIZE) compiler option.  They also do not recognize that
    the list of invalid options is listed immediately below the
    message, in the assembler listing output for IGYCDOPT.
    
    The original error message produced by the MNOTE in the IGYCOPT
    macro was not clear enough and seemed to imply that there was a
    problem with the OPT compiler option, when it was actually
    referring to any compiler OPTION.  The message also did not
    instruct the administrator to look for the badly formatted or
    unknown compiler options immediately following the MNOTE error
    message in the assembler listing.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All administrators of the z/OS Enterprise    *
    *                 COBOL V6.2 Compiler who are planning to      *
    *                 modify compiler option default values by     *
    *                 building the IGYCDOPT program.               *
    ****************************************************************
    * PROBLEM DESCRIPTION: APAR PH36777 added code to              *
    *                      SIGYMAC(IGYCOPT) to recognize the       *
    *                      problem when administrators incorrectly *
    *                      coded OPTION( ) instead of OPTION=( ),  *
    *                      or coded an unknown compiler option.    *
    *                      Administrators are getting confused     *
    *                      because the message says OPT=VALUE      *
    *                      instead of OPTION=VALUE,  and           *
    *                      mistakenly think that there is a        *
    *                      problem with the OPT (OPTIMIZE)         *
    *                      compiler option.  They also do not      *
    *                      recognize that the list of invalid      *
    *                      options is listed immediately below the *
    *                      message, in the assembler listing       *
    *                      output for igycdopt.                    *
    ****************************************************************
    * RECOMMENDATION: Apply the IBM provided PTF                   *
    ****************************************************************
    The original error message produced by the MNOTE in the IGYCOPT
    macro was not clear enough and seemed to imply that there was a
    problem with the OPT compiler option, when it was actually
    referring to any compiler OPTION.  The message also did not
    instruct the administrator to look for the badly formatted or
    unknown compiler options to immediately follow the error message
    in the assembler listing.
    

Problem conclusion

  • The MNOTE error message produced when an incorrectly formatted
    or unknown compiler option is specified in the IGYCDOPT
    assembler file has been reworded to clearly identify the
    problem.   It also now instructs the admin to look for the
    unknown or badly formatted options to immediately follow this
    message in the assembler listing.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH41479

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-10-20

  • Closed date

    2021-10-21

  • Last modified date

    2021-11-01

  • APAR is sysrouted FROM one or more of the following:

    PH40314

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI
    IGYCOPT  IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL
    IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3
    IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV
    IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU
    IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI77740

       UP21/10/30 P F110

  • R621 PSY UI77741

       UP21/10/30 P F110

  • R622 PSY UI77742

       UP21/10/30 P F110

  • R62H PSY UI77743

       UP21/10/30 P F110

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: