Fixes are available
APAR status
Closed as program error.
Error description
As the runtimes must be installed in the same WAS server or cluster than the administration services it is impossible in WAS ND to install runtimes in different servers or clusters than the console. It provokes two problems : 1) Inability to partition and scale clusters or servers according to mobile app SLAs 2) Inability to define seperate WebSphere security domains for the console and the runtimes so use different user registries (LDAP servers) between console and runtimes
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Worklight administrators * **************************************************************** * PROBLEM DESCRIPTION: * * Currently runtimes must be installed in the same WAS server * * or cluster than the administration services it is impossible * * in WAS ND to install runtimes in different servers or * * clusters than the console. It provokes two problems : * * * * 1) Inability to partition and scale clusters or servers * * according to mobile app SLAs * * 2) Inability to define seperate WebSphere security domains * * for the console and the runtimes so use different user * * registries (LDAP servers) between console and runtimes * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
Now non symmetric deployment is also supported meaning that the Worklight runtimes can be deployed in a WAS ND cell in another cluster/server than the admin services that administrates them.
Temporary fix
Comments
APAR Information
APAR number
PI35384
Reported component name
WL/MFPF CONSUME
Reported component ID
5725I4301
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-02-19
Closed date
2015-02-24
Last modified date
2015-02-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WL/MFPF CONSUME
Fixed component ID
5725I4301
Applicable component levels
R620 PSY
UP
R630 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021