A fix is available
APAR status
Closed as program error.
Error description
With the server config tool, on a Liberty Server - Install 2 configuraitons Configuration 1 and configuration 2 with different context root for the admin and the console - Start the Liberty server - verify you can access both - Stop the Liberty server - Remove configuration 1 from server - Start the Liberty server, try to access configuration 2 then Configuration 2 is not available Cause of problem: usr\servers\<serverName>\apps\worklightadmin.war and usr\servers\<serverName>\apps\worklightconsole.war have been removed from the server. That is above two war fiels are used by two applications. But they are removed when the first configuration is uninstalled. Reference: RTC defect#: 53809
Local fix
The workaround would be to re-copy again the WAR file after the configuration 1 is removed. They are located in <WorklightInstallDir>/WorklightServer
Problem summary
**************************************************************** * USERS AFFECTED: * * Administrators and developers deployng multiple Worklight * * configurations on the same Liberty Server with the Server * * Configuration Tool or with ant tasks. * **************************************************************** * PROBLEM DESCRIPTION: * * The uninstallof a Worklight configuration removes all WAR * * files installed at install time. In the case of multiple * * configurations, the WAR files of the console and admin * * service are shared between multiple configurations. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
WAR files shared by other installed applications are not removed when a configuration is uninstalled.
Temporary fix
Comments
APAR Information
APAR number
PI27421
Reported component name
WORKLIGHT ENTER
Reported component ID
5725I4300
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-10-10
Closed date
2014-10-29
Last modified date
2014-10-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT ENTER
Fixed component ID
5725I4300
Applicable component levels
R620 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
17 October 2021