Fixes are available
APAR status
Closed as program error.
Error description
If a Windows 8 app calls WL.SimpleDialog 2 times consecutively, the app will crash. If run in Visual Studio, a pop up may be displayed with output similar to the following: -------------- Unhandled exception at line 2784, column 13 in ms-appx:0a37ad09--41af-483d-af2e-aa9f85efec69/www/default/workli ght/worklight.js 0x80070005 - JavaScript runtime error: Access is denied. --------------
Local fix
It is a limitation of Windows 8 that no more than 1 dialog may be opened at a time. However, a crash should not occur. To open 2 dialogs and avoid the crash, the second dialog can be called on the callback of the first dialog's button.
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of the WL.SimpleDialog.show() API on the Windows 8 * * environment * **************************************************************** * PROBLEM DESCRIPTION: * * If a second WL.SimpleDialog.show() call is made when the * * first SimpleDialog has not yet been dismissed, the Windows 8 * * application will crash. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
Windows platform has a limitation that doesn't allow a second MessageDialogs to be displayed when the first one is active. This has been accounted for in the fix.
Temporary fix
Comments
APAR Information
APAR number
PI34910
Reported component name
WL/MFPF CONSUME
Reported component ID
5725I4301
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-02-12
Closed date
2015-05-18
Last modified date
2015-05-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WL/MFPF CONSUME
Fixed component ID
5725I4301
Applicable component levels
R630 PSY
UP
R700 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
16 October 2021